docs: refactor the "power" configuration docs

Add the "status_delay" option for Home Assistant and refactor to clarify what each option does for each device type.

Signed-off-by:  Eric Callahan <arksine.code@gmail.com>
This commit is contained in:
Eric Callahan 2021-11-15 11:01:03 -05:00
parent 1caaebe03f
commit df1892801f
1 changed files with 74 additions and 57 deletions

View File

@ -298,6 +298,8 @@ bound_service:
# been set the service will be started when the device powers on and stopped # been set the service will be started when the device powers on and stopped
# when the device powers off. The default is no service is bound to the # when the device powers off. The default is no service is bound to the
# device. # device.
#
# *** The following options apply to "gpio" and "rf" types ***
pin: gpiochip0/gpio26 pin: gpiochip0/gpio26
# The pin to use for GPIO and RF devices. The chip is optional, if left out # The pin to use for GPIO and RF devices. The chip is optional, if left out
# then the module will default to gpiochip0. If one wishes to invert # then the module will default to gpiochip0. If one wishes to invert
@ -318,80 +320,95 @@ timer:
# devices. The timer may be a floating point value for gpio types, it should # devices. The timer may be a floating point value for gpio types, it should
# be an integer for all other types. The default is no timer is set. # be an integer for all other types. The default is no timer is set.
# #
address: # *** The following options apply to "rf" devices ***
port: on_code:
# The above options are used for "tplink_smartplug" devices. The off_code:
# address should be a valid ip or hostname for the tplink device. # Valid binary codes that are sent via the RF transmitter.
# The port should be the port the device is configured to use. # For example: 1011.
# "Power Strips" can be controlled by including the socket index
# in the ip address. For example, to control socket index 1:
# 192.168.1.127/1
# The address must be provided. The port defaults to 9999.
# #
# *** The following options apply to "tplink_smartplug" devices ***
address: address:
password: # A valid ip address or hostname for the tplink device. "Power Strips" can
output_id: # be controlled by including the socket index in the ip address. For example,
# The above options are used for "tasmota" devices. The # to control socket index 1:
# address should be a valid ip or hostname for the tasmota device. # 192.168.1.127/1
# Provide a password if configured in Tasmota (default is empty). # This parameter must be provided.
# Provided an output_id (relay id) if the Tasmota device supports port:
# more than one (default is 1). # The port to connect to. Default is 9999.
#
# *** The following options apply to "tasmota" devices ***
# Note:
# If your single-relay Tasmota device switches on/off successfully, # If your single-relay Tasmota device switches on/off successfully,
# but fails to report its state, ensure that 'SetOption26' is set in # but fails to report its state, ensure that 'SetOption26' is set in
# Tasmota. # Tasmota.
#
address: address:
user: # A valid ip address or hostname for the tasmota device. This parameter
# must be provided.
password: password:
# A password used to authenticate requests. Default is no password.
output_id: output_id:
# The above options are used for "shelly" devices. The # The output_id (or relay id) to use if the Tasmota device supports
# address should be a valid ip or hostname for the Shelly device. # more than one output. Default is 1.
# Provide a user and password if configured in Shelly (default is empty).
# If password is set but user is empty the default user "admin" will be used
# Provided an output_id (relay id) if the Shelly device supports
# more than one (default is 0).
# #
# *** The following options apply to "shelly" devices ***
address: address:
device: # A valid ip address or hostname for the shelly device. This parameter
# must be provided.
user: user:
# A user name to use for request authentication. If no password is set
# the the default is no user, otherwise the default is "admin".
password: password:
# The above options are used for "homeseer" devices. The # The password to use for request authentication. The default is no
# address should be a valid ip or hostname for the homeseer controller. # password.
# "device" should be the ID of the device to control. output_id:
# To find out the ID, in the HomeSeer UI, click on the device you want to # The output_id (or relay id) to use if the Shelly device supports
# more than one output. Default is 1.
#
# *** The following options apply to "homeseer" devices ***
address:
# A valid ip address or hostname for the homeseer device. This parameter
# must be provided.
device:
# The ID of the device to control.
# To find out the ID in the HomeSeer UI, click on the device you want to
# control (Make sure to click the sub-device that actually has On/Off # control (Make sure to click the sub-device that actually has On/Off
# buttons). And then go to the "status/graphics" tab and it should list # buttons). And then go to the "status/graphics" tab and it should list
# "ID" in the "advanced information" section. # "ID" in the "advanced information" section. This parameter must be
# Provide a user and password with access to "device control" # provided.
# and at least the specific device you want to control
#
address:
port:
device:
token:
domain:
# The above options are used for "homeassistant" devices. The
# address should be a valid ip or hostname for the homeassistant controller.
# "device" should be the ID of the switch to control.
# "domain" is the class of device set managed by homeassistant, defaults to "switch".
#
address:
user: user:
# The user name for request authentication. This default is "admin".
password: password:
output_id: # The password for request authentication. The default is no password.
# The above options are used for "loxone smart home miniserver v1 " devices.
# The address should be a valid ip or hostname for the loxone miniserver v1
# device. All entries must be configured in advance in the loxone config.
# Provide a user and password configured in loxone config.
# The output_id is the name of a programmed output, virtual input or virtual
# output in the loxone config his output_id (name) may only be used once in
# the loxone config
# #
on_code: # *** The following options apply to "homeassistant" devices ***
off_code: address:
# The above options are used for "rf" devices. The # A valid ip address or hostname for the Home Assistant server. This
# codes should be valid binary codes that are send via the RF transmitter. # parameter must be provided.
# For example: 1011. port:
# The port the Home Assistant server is listening on. Default is 8123.
device:
# The device ID of the switch to control. This parameter must be provided.
token:
# A token used for request authorization. This paramter must be provided.
domain:
# The class of device managed by Home Assistant. Default is "switch".
status_delay: 1.0
# The time (in seconds) to delay between requesting a device to turn
# on/off and requesting its current status. This is a workaround used
# to validate that Home Assistant has successfully toggled the device,
# as the API is currently broken on their end. Default is 1 second.
#
# *** The following options apply to "loxone" devices ***
address:
# A valid ip address or hostname for the Loxone server. This
# parameter must be provided.
user:
# The user name used for request authorization. The default is "admin".
password:
# The password used for request authorization. The default is "admin".
output_id:
# The name of a programmed output, virtual input or virtual
# output in the loxone configuration. The default is no output id.
``` ```
!!! Tip !!! Tip