diff --git a/docs/configuration.md b/docs/configuration.md index c00437c..056bd4f 100644 --- a/docs/configuration.md +++ b/docs/configuration.md @@ -229,22 +229,26 @@ initial_state: off # The initial state for GPIO type devices. May be on or # off. When moonraker starts the device will be set to this # state. Default is off. +timer: +# A time (in seconds) after which the device will power off after being. +# switched on. This effectively turns the device into a momentary switch. +# This option is available for gpio, tplink_smartplug, shelly, and tasmota +# devices. The timer may be a floating point value for gpio types, it should +# be an integer for all other types. The default is no timer is set. +# address: port: -timer: # The above options are used for "tplink_smartplug" devices. The # address should be a valid ip or hostname for the tplink device. # The port should be the port the device is configured to use. -# The timer option is used to delay the turn off for x sec when -# its already on. # "Power Strips" can be controlled by including the socket index # in the ip address. For example, to control socket index 1: # 192.168.1.127/1 # The address must be provided. The port defaults to 9999. +# address: password: output_id: -timer: # The above options are used for "tasmota" devices. The # address should be a valid ip or hostname for the tasmota device. # Provide a password if configured in Tasmota (default is empty). @@ -253,20 +257,18 @@ timer: # If your single-relay Tasmota device switches on/off successfully, # but fails to report its state, ensure that 'SetOption26' is set in # Tasmota. +# address: user: password: output_id: -timer: # The above options are used for "shelly" devices. The # address should be a valid ip or hostname for the Shelly device. # Provide a user and password if configured in Shelly (default is empty). # If password is set but user is empty the default user "admin" will be used # Provided an output_id (relay id) if the Shelly device supports -# more than one (default is 0). When timer option is used to delay the turn -# off make sure to set the state to "on" in action call_remote_method. -# So we send a command to turn it on for x sec when its already on then -# it turns off. +# more than one (default is 0). +# address: device: user: @@ -280,6 +282,7 @@ password: # "ID" in the "advanced information" section. # Provide a user and password with access to "device control" # and at least the specific device you want to control +# address: port: device: @@ -289,6 +292,7 @@ domain: # address should be a valid ip or hostname for the homeassistant controller. # "device" should be the ID of the switch to control. # "domain" is the class of device set managed by homeassistant, defaults to "switch". +# address: user: password: @@ -300,6 +304,7 @@ output_id: # The output_id is the name of a programmed output, virtual input or virtual # output in the loxone config his output_id (name) may only be used once in # the loxone config +# on_code: off_code: # The above options are used for "rf" devices. The