# Using PWM tools
This document describes how to setup a PWM-controlled laser or spindle
using `output_pin` and some macros.
## How does it work?
With re-purposing the printhead's fan pwm output, you can control
lasers or spindles.
This is useful if you use switchable print heads, for example
the E3D toolchanger or a DIY solution.
Usually, cam-tools such as LaserWeb can be configured to use `M3-M5`
commands, which stand for _spindle speed CW_ (`M3 S[0-255]`),
_spindle speed CCW_ (`M4 S[0-255]`) and _spindle stop_ (`M5`).
**Warning:** When driving a laser, keep all security precautions
that you can think of! Diode lasers are usually inverted.
This means, that when the MCU restarts, the laser will be
_fully on_ for the time it takes the MCU to start up again.
For good measure, it is recommended to _always_ wear appropriate
laser-goggles of the right wavelength if the laser is powered;
and to disconnect the laser when it is not needed.
Also, you should configure a safety timeout,
so that when your host or MCU encounters an error, the tool will stop.
For an example configuration, see `config/sample-pwm-tool-cfg`.
## Current Limitations
There is a limitation of how frequent PWM updates may occur.
While being very precise, a PWM update may only occur every 0.1 seconds,
rendering it almost useless for raster engraving.
However, there exists an [experimental branch](https://github.com/Cirromulus/klipper/tree/laser_tool) with its own tradeoffs.
In long term, it is planned to add this functionality to main-line klipper.
## Commands
`M3/M4 S<value>` : Set PWM duty-cycle. Values between 0 and 255.
`M5` : Stop PWM output to shutdown value.
## Laserweb Configuration
If you use Laserweb, a working configuration would be:
GCODE START:
M5 ; Disable Laser
G21 ; Set units to mm
G90 ; Absolute positioning
G0 Z0 F7000 ; Set Non-Cutting speed
GCODE END:
M5 ; Disable Laser
G91 ; relative
G0 Z+20 F4000 ;
G90 ; absolute
GCODE HOMING:
M5 ; Disable Laser
G28 ; Home all axis
TOOL ON:
M3 $INTENSITY
TOOL OFF:
M5 ; Disable Laser
LASER INTENSITY:
S