Measuring Resonances
|
|
====================
|
|
|
|
Klipper has built-in support for ADXL345 accelerometer, which can be used to
|
|
measure resonance frequencies of the printer for different axes, and auto-tune
|
|
[input shapers](Resonance_Compensation.md) to compensate for resonances.
|
|
Note that using ADXL345 requires some soldering and crimping. ADXL345 can be
|
|
connected to a Raspberry Pi directly, or to an SPI interface of an MCU
|
|
board (it needs to be reasonably fast).
|
|
|
|
|
|
Installation instructions
|
|
===========================
|
|
|
|
## Wiring
|
|
|
|
You need to connect ADXL345 to your Raspberry Pi via SPI. Note that the I2C
|
|
connection, which is suggested by ADXL345 documentation, has too low throughput
|
|
and **will not work**. The recommended connection scheme:
|
|
|
|
| ADXL345 pin | RPi pin | RPi pin name |
|
|
|:--:|:--:|:--:|
|
|
| 3V3 (or VCC) | 01 | 3.3v DC power |
|
|
| GND | 06 | Ground |
|
|
| CS | 24 | GPIO08 (SPI0_CE0_N) |
|
|
| SDO | 21 | GPIO09 (SPI0_MISO) |
|
|
| SDA | 19 | GPIO10 (SPI0_MOSI) |
|
|
| SCL | 23 | GPIO11 (SPI0_SCLK) |
|
|
|
|
Fritzing wiring diagrams for some of the ADXL345 boards:
|
|
|
|
![ADXL345-Rpi](img/adxl345-fritzing.png)
|
|
|
|
|
|
Double-check your wiring before powering up the Raspberry Pi to prevent
|
|
damaging it or the accelerometer.
|
|
|
|
## Mounting the accelerometer
|
|
|
|
The accelerometer must be attached to the toolhead. One needs to design a proper
|
|
mount that fits their own 3D printer. It is better to align the axes of the
|
|
accelerometer with the printer's axes (but if it makes it more convenient,
|
|
axes can be swapped - i.e. no need to align X axis with X and so forth - it
|
|
should be fine even if Z axis of accelerometer is X axis of the printer, etc.).
|
|
|
|
An example of mounting ADXL345 on the SmartEffector:
|
|
|
|
![ADXL345 on SmartEffector](img/adxl345-mount.jpg)
|
|
|
|
Note that on a bed slinger printer one must design 2 mounts: one for the
|
|
toolhead and one for the bed, and run the measurements twice. See the
|
|
corresponding [section](#bed-slinger-printers) for more details.
|
|
|
|
## Software installation
|
|
|
|
Note that resonance measurements and shaper auto-calibration require additional
|
|
software dependencies not installed by default. First, you will have to run on
|
|
your Raspberry Pi the following command:
|
|
```
|
|
~/klippy-env/bin/pip install -v numpy
|
|
```
|
|
to install `numpy` package. Note that, depending on the performance of the
|
|
CPU, it may take *a lot* of time, up to 10-20 minutes. Be patient and wait
|
|
for the completion of the installation. On some occasions, if the board has
|
|
too little RAM, the installation may fail and you will need to enable swap.
|
|
|
|
Next, run the following command to install the additional dependencies:
|
|
```
|
|
sudo apt install python-numpy python-matplotlib
|
|
```
|
|
|
|
Afterwards, check and follow the instructions in the
|
|
[RPi Microcontroller document](RPi_microcontroller.md) to setup the
|
|
"linux mcu" on the Raspberry Pi.
|
|
|
|
Make sure the Linux SPI driver is enabled by running `sudo
|
|
raspi-config` and enabling SPI under the "Interfacing options" menu.
|
|
|
|
Add the following to the printer.cfg file:
|
|
```
|
|
[mcu rpi]
|
|
serial: /tmp/klipper_host_mcu
|
|
|
|
[adxl345]
|
|
cs_pin: rpi:None
|
|
|
|
[resonance_tester]
|
|
accel_chip: adxl345
|
|
probe_points:
|
|
100,100,20 # an example
|
|
```
|
|
It is advised to start with 1 probe point, in the middle of the print bed,
|
|
slightly above it.
|
|
|
|
Restart Klipper via the `RESTART` command.
|
|
|
|
Measuring the resonances
|
|
===========================
|
|
|
|
## Checking the setup
|
|
|
|
Now you can test a connection. In Octoprint, run `ACCELEROMETER_QUERY`. You
|
|
should see the current measurements from the accelerometer, including the
|
|
free-fall acceleration, e.g.
|
|
```
|
|
Recv: // adxl345 values (x, y, z): 470.719200, 941.438400, 9728.196800
|
|
```
|
|
|
|
If you get an error like `Invalid adxl345 id (got xx vs e5)`, where `xx`
|
|
is some other ID, it is indicative of the connection problem with ADXL345,
|
|
or the faulty sensor. Double-check the power, the wiring (that it matches
|
|
the schematics, no wire is broken or loose, etc.), and soldering quality.
|
|
|
|
Next, try running `MEASURE_AXES_NOISE` in Octoprint, you should get some
|
|
baseline numbers for the noise of accelerometer on the axes (should be
|
|
somewhere in the range of ~1-100).
|
|
|
|
## Measuring the resonances
|
|
|
|
Now you can run some real-life tests. In `printer.cfg` add or replace the
|
|
following values:
|
|
```
|
|
[printer]
|
|
max_accel: 7000
|
|
max_accel_to_decel: 7000
|
|
```
|
|
(after you are done with the measurements, revert these values to their old,
|
|
or the newly suggested values). Also, if you have enabled input shaper already,
|
|
you will need to disable it prior to this test as follows:
|
|
```
|
|
SET_INPUT_SHAPER SHAPER_FREQ_X=0 SHAPER_FREQ_Y=0
|
|
```
|
|
as it is not valid to run the resonance testing with the input shaper enabled.
|
|
|
|
Run the following command:
|
|
```
|
|
TEST_RESONANCES AXIS=X
|
|
```
|
|
Note that it will create vibrations on X axis.
|
|
|
|
**Attention!** Be sure to observe the printer for the first time, to make sure
|
|
the vibrations do not become too violent (`M112` command can be used to abort
|
|
the test in case of emergency; hopefully it will not come to this though).
|
|
If the vibrations do get too strong, you can attempt to specify a lower than the
|
|
default value for `accel_per_hz` parameter in `[resonance_tester]` section, e.g.
|
|
```
|
|
[resonance_tester]
|
|
accel_chip: adxl345
|
|
accel_per_hz: 50 # default is 75
|
|
probe_points: ...
|
|
```
|
|
|
|
If it works for X axis, run for Y axis as well:
|
|
```
|
|
TEST_RESONANCES AXIS=Y
|
|
```
|
|
This will generate 2 CSV files (`/tmp/resonances_x_*.csv` and
|
|
`/tmp/resonances_y_*.csv`). These files can be processed with the stand-alone
|
|
script on a Raspberry Pi. To do that, run running the following commands:
|
|
```
|
|
~/klipper/scripts/calibrate_shaper.py /tmp/resonances_x_*.csv -o /tmp/shaper_calibrate_x.png
|
|
~/klipper/scripts/calibrate_shaper.py /tmp/resonances_y_*.csv -o /tmp/shaper_calibrate_y.png
|
|
```
|
|
This script will generate the charts `/tmp/shaper_calibrate_x.png` and
|
|
`/tmp/shaper_calibrate_y.png` with frequency responses. You will also get the
|
|
suggested frequencies for each input shaper, as well as which input shaper is
|
|
recommended for your setup. For example:
|
|
|
|
![Resonances](img/calibrate-y.png)
|
|
```
|
|
Fitted shaper 'zv' frequency = 37.0 Hz (vibrations = 29.1%, smoothing ~= 0.115)
|
|
Fitted shaper 'mzv' frequency = 35.4 Hz (vibrations = 15.9%, smoothing ~= 0.163)
|
|
Fitted shaper 'ei' frequency = 42.0 Hz (vibrations = 15.1%, smoothing ~= 0.183)
|
|
Fitted shaper '2hump_ei' frequency = 45.6 Hz (vibrations = 9.7%, smoothing ~= 0.260)
|
|
Fitted shaper '3hump_ei' frequency = 59.0 Hz (vibrations = 7.5%, smoothing ~= 0.235)
|
|
Recommended shaper is 3hump_ei @ 59.0 Hz
|
|
```
|
|
|
|
The suggested configuration can be added to `[input_shaper]` section of
|
|
`printer.cfg`, e.g.:
|
|
```
|
|
[input_shaper]
|
|
shaper_freq_x: ...
|
|
shaper_type_x: ...
|
|
shaper_freq_y: 59.0
|
|
shaper_type_y: 3hump_ei
|
|
```
|
|
or you can choose some other configuration yourself based on the generated
|
|
charts: peaks in the power spectral density on the charts correspond to
|
|
the resonance frequencies of the printer.
|
|
|
|
Note that alternatively you can run the input shaper autocalibration
|
|
from Klipper [directly](#input-shaper-auto-calibration), which can be
|
|
convenient, for example, for the input shaper
|
|
[re-calibration](#input-shaper-re-calibration).
|
|
|
|
## Bed-slinger printers
|
|
|
|
If your printer is a bed slinger printer, you will need to change the location
|
|
of the accelerometer between the measurements for X and Y axes: measure the
|
|
resonances of X axis with the accelerometer attached to the toolhead and the
|
|
resonances of Y axis - to the bed (the usual bed slinger setup).
|
|
|
|
However, you can also connect two accelerometers simultaneously, though they
|
|
must be connected to different boards (say, to an RPi and printer MCU board), or
|
|
to two different physical SPI interfaces on the same board (rarely available).
|
|
Then they can be configured in the following manner:
|
|
```
|
|
[adxl345 adxl345_x]
|
|
# Assuming adxl345_x is connected to an RPi
|
|
cs_pin: rpi:None
|
|
|
|
[adxl345 adxl345_y]
|
|
# Assuming adxl345_y is connected to a printer MCU board
|
|
cs_pin: ... # Printer board SPI chip select (CS) pin
|
|
|
|
[resonance_tester]
|
|
accel_chip_x: adxl345_x
|
|
accel_chip_y: adxl345_y
|
|
probe_points: ...
|
|
```
|
|
|
|
Then the commands `TEST_RESONANCES AXIS=X` and `TEST_RESONANCES AXIS=Y`
|
|
will use the correct accelerometer for each axis.
|
|
|
|
## Max smoothing
|
|
|
|
Keep in mind that the input shaper can create some smoothing in parts.
|
|
Automatic tuning of the input shaper performed by `calibrate_shaper.py`
|
|
script or `SHAPER_CALIBRATE` command tries not to exacerbate the smoothing,
|
|
but at the same time they try to minimize the resulting vibrations.
|
|
Sometimes they can make a sub-optimal choice of the shaper frequency, or
|
|
maybe you simply prefer to have less smoothing in parts at the expense of
|
|
a larger remaining vibrations. In these cases, you can request to limit
|
|
the maximum smoothing from the input shaper.
|
|
|
|
Let's consider the following results from the automatic tuning:
|
|
|
|
![Resonances](img/calibrate-x.png)
|
|
```
|
|
Fitted shaper 'zv' frequency = 62.2 Hz (vibrations = 36.9%, smoothing ~= 0.046)
|
|
Fitted shaper 'mzv' frequency = 35.6 Hz (vibrations = 18.1%, smoothing ~= 0.161)
|
|
Fitted shaper 'ei' frequency = 54.6 Hz (vibrations = 19.3%, smoothing ~= 0.108)
|
|
Fitted shaper '2hump_ei' frequency = 46.2 Hz (vibrations = 9.2%, smoothing ~= 0.253)
|
|
Fitted shaper '3hump_ei' frequency = 50.0 Hz (vibrations = 7.2%, smoothing ~= 0.328)
|
|
Recommended shaper is 2hump_ei @ 46.2 Hz
|
|
```
|
|
Note that the reported `smoothing` values are some abstract projected values.
|
|
These values can be used to compare different configurations: the higher the
|
|
value, the more smoothing a shaper will create. However, these smoothing scores
|
|
do not represent any real measure of smoothing, because the actual smoothing
|
|
depends on [`max_accel`](#selecting-max-accel) and `square_corner_velocity`
|
|
parameters. Therefore, you should print some test prints to see how much
|
|
smoothing exactly a chosen configuration creates.
|
|
|
|
In the example above the suggested shaper parameters are not bad, but what if
|
|
you want to get less smoothing on the X axis? You can try to limit the maximum
|
|
shaper smoothing using the following command:
|
|
```
|
|
~/klipper/scripts/calibrate_shaper.py /tmp/resonances_x_*.csv -o /tmp/shaper_calibrate_x.png --max_smoothing=0.2
|
|
```
|
|
which limits the smoothing to 0.2 score. Now you can get the following result:
|
|
|
|
![Resonances](img/calibrate-x-max-smoothing.png)
|
|
```
|
|
Fitted shaper 'zv' frequency = 55.2 Hz (vibrations = 34.2%, smoothing ~= 0.057)
|
|
Fitted shaper 'mzv' frequency = 33.8 Hz (vibrations = 17.4%, smoothing ~= 0.178)
|
|
Fitted shaper 'ei' frequency = 47.4 Hz (vibrations = 17.6%, smoothing ~= 0.143)
|
|
Fitted shaper '2hump_ei' frequency = 52.0 Hz (vibrations = 11.9%, smoothing ~= 0.200)
|
|
Fitted shaper '3hump_ei' frequency = 75.0 Hz (vibrations = 9.7%, smoothing ~= 0.146)
|
|
Recommended shaper is 3hump_ei @ 75.0 Hz
|
|
```
|
|
|
|
If you compare to the previously suggested parameters, the vibrations are a bit
|
|
larger, but the smoothing is significantly smaller than previously.
|
|
|
|
When deciding which `max_smoothing` parameter to choose, you can use a
|
|
trial-and-error approach. Try a few different values and see which results
|
|
you get. Note however that if you request the script to find a configuration
|
|
for your printer with an unrealistically small smoothing, it will be unable
|
|
to find a reasonable configuration. The suggested parameters will have a poor
|
|
performance in this case and you can get too much remaining ringing as a result.
|
|
So, always double-check the projected remaining vibrations and make sure they
|
|
are not too high.
|
|
|
|
Note that if you chose a good `max_smoothing` value for both of your axes, you
|
|
can store it in the `printer.cfg` as
|
|
```
|
|
[resonance_tester]
|
|
accel_chip: ...
|
|
probe_points: ...
|
|
max_smoothing: 0.25 # an example
|
|
```
|
|
Then, if you [rerun](#input-shaper-re-calibration) the input shaper auto-tuning
|
|
using `SHAPER_CALIBRATE` Klipper command in the future, it will use the stored
|
|
`max_smoothing` value as a reference.
|
|
|
|
## Selecting max_accel
|
|
|
|
Since the input shaper can create some smoothing in parts, especially at high
|
|
accelerations, you will still need to choose the `max_accel` value that
|
|
does not create too much smoothing in the printed parts. Follow
|
|
[this](Resonance_Compensation.md#selecting-max_accel) part of
|
|
the input shaper tuning guide and print the test model.
|
|
|
|
The same notice applies to the input shaper
|
|
[auto-calibration](#input-shaper-auto-calibration) with
|
|
`SHAPER_CALIBRATE` command: it is still necessary to choose the right
|
|
`max_accel` value after the auto-calibration.
|
|
|
|
If you are doing a shaper re-calibration and the reported smoothing for the
|
|
suggested shaper configuration is almost the same as what you got during the
|
|
previous calibration, this step can be skipped.
|
|
|
|
|
|
# Input Shaper auto-calibration
|
|
|
|
Besides manually choosing the appropriate parameters for the input shaper
|
|
feature, it is also possible to run the auto-tuning for the input shaper
|
|
directly from Klipper. Run the following command via Octoprint terminal:
|
|
```
|
|
SHAPER_CALIBRATE
|
|
```
|
|
|
|
This will run the full test for both axes and generate the csv output
|
|
(`/tmp/calibration_data_*.csv` by default) for the frequency response
|
|
and the suggested input shapers. You will also get the suggested
|
|
frequencies for each input shaper, as well as which input shaper is
|
|
recommended for your setup, on Octoprint console. For example:
|
|
|
|
```
|
|
Fitted shaper 'zv' frequency = 56.7 Hz (vibrations = 23.2%)
|
|
Fitted shaper 'mzv' frequency = 52.9 Hz (vibrations = 10.9%)
|
|
Fitted shaper 'ei' frequency = 62.0 Hz (vibrations = 8.9%)
|
|
Fitted shaper '2hump_ei' frequency = 59.0 Hz (vibrations = 4.9%)
|
|
Fitted shaper '3hump_ei' frequency = 65.0 Hz (vibrations = 3.3%)
|
|
Recommended shaper_type_y = 2hump_ei, shaper_freq_y = 59.0 Hz
|
|
```
|
|
If you agree with the suggested parameters, you can execute `SAVE_CONFIG`
|
|
now to save them and restart the Klipper.
|
|
|
|
|
|
If your printer is a bed slinger printer, you can specify which axis
|
|
to test, so that you can change the accelerometer mounting point between
|
|
the tests (by default the test is performed for both axes):
|
|
```
|
|
SHAPER_CALIBRATE AXIS=Y
|
|
```
|
|
|
|
You can execute `SAVE_CONFIG` twice - after calibrating each axis.
|
|
|
|
However, if you connected two accelerometers simultaneously, you simply run
|
|
`SHAPER_CALIBRATE` without specifying an axis to calibrate the input shaper
|
|
for both axes in one go.
|
|
|
|
## Input Shaper re-calibration
|
|
|
|
`SHAPER_CALIBRATE` command can be also used to re-calibrate the input shaper in
|
|
the future, especially if some changes to the printer that can affect its
|
|
kinematics are made. One can either re-run the full calibration using
|
|
`SHAPER_CALIBRATE` command, or restrict the auto-calibration to a single axis by
|
|
supplying `AXIS=` parameter, like
|
|
```
|
|
SHAPER_CALIBRATE AXIS=X
|
|
```
|
|
|
|
**Warning!** It is not advisable to run the shaper autocalibration very
|
|
frequently (e.g. before every print, or every day). In order to determine
|
|
resonance frequencies, autocalibration creates intensive vibrations on each of
|
|
the axes. Generally, 3D printers are not designed to withstand a prolonged
|
|
exposure to vibrations near the resonance frequencies. Doing so may increase
|
|
wear of the printer components and reduce their lifespan. There is also an
|
|
increased risk of some parts unscrewing or becoming loose. Always check that
|
|
all parts of the printer (including the ones that may normally not move) are
|
|
securely fixed in place after each auto-tuning.
|
|
|
|
Also, due to some noise in measurements, it is possible that the tuning results
|
|
will be slightly different from one calibration run to another one. Still, it
|
|
is not expected that the noise will affect the print quality too much.
|
|
However, it is still advised to double-check the suggested parameters, and
|
|
print some test prints before using them to confirm they are good.
|
|
|
|
# Offline processing of the accelerometer data
|
|
|
|
It is possible to generate the raw accelerometer data and process it offline
|
|
(e.g. on a host machine), for example to find resonances. In order to do so,
|
|
run the following commands via Octoprint terminal:
|
|
```
|
|
SET_INPUT_SHAPER SHAPER_FREQ_X=0 SHAPER_FREQ_Y=0
|
|
TEST_RESONANCES AXIS=X OUTPUT=raw_data
|
|
```
|
|
ignoring any errors for `SET_INPUT_SHAPER` command. For `TEST_RESONANCES`
|
|
command, specify the desired test axis. The raw data will be written into
|
|
`/tmp` directory on the RPi.
|
|
|
|
The raw data can also be obtained by running the command `ACCELEROMETER_MEASURE`
|
|
command twice during some normal printer activity - first to start the
|
|
measurements, and then to stop them and write the output file. Refer to
|
|
[G-Codes](G-Codes.md#adxl345-accelerometer-commands) for more details.
|
|
|
|
The data can be processed later by the following scripts:
|
|
`scripts/graph_accelerometer.py` and `scripts/calibrate_shaper.py`. Both
|
|
of them accept one or several raw csv files as the input depending on the
|
|
mode. The graph_accelerometer.py script supports several modes of operation:
|
|
|
|
* plotting raw accelerometer data (use `-r` parameter), only 1 input is
|
|
supported;
|
|
* plotting a frequency response (no extra parameters required), if multiple
|
|
inputs are specified, the average frequency response is computed;
|
|
* comparison of the frequency response between several inputs (use `-c`
|
|
parameter); you can additionally specify which accelerometer axis to
|
|
consider via `-a x`, `-a y` or `-a z` parameter (if none specified,
|
|
the sum of vibrations for all axes is used);
|
|
* plotting the spectrogram (use `-s` parameter), only 1 input is supported;
|
|
you can additionally specify which accelerometer axis to consider via
|
|
`-a x`, `-a y` or `-a z` parameter (if none specified, the sum of vibrations
|
|
for all axes is used).
|
|
|
|
Note that graph_accelerometer.py script supports only the raw_data\*.csv files
|
|
and not resonances\*.csv or calibration_data\*.csv files.
|
|
|
|
For example,
|
|
```
|
|
~/klipper/scripts/graph_accelerometer.py /tmp/raw_data_x_*.csv -o /tmp/resonances_x.png -c -a z
|
|
```
|
|
will plot the comparison of several `/tmp/raw_data_x_*.csv` files for Z axis to
|
|
`/tmp/resonances_x.png` file.
|
|
|
|
The shaper_calibrate.py script accepts 1 or several inputs and can run automatic
|
|
tuning of the input shaper and suggest the best parameters that work well for
|
|
all provided inputs. It prints the suggested parameters to the console, and can
|
|
additionally generate the chart if `-o output.png` parameter is provided, or
|
|
the CSV file if `-c output.csv` parameter is specified.
|
|
|
|
Providing several inputs to shaper_calibrate.py script can be useful if running
|
|
some advanced tuning of the input shapers, for example:
|
|
|
|
* Running `TEST_RESONANCES AXIS=X OUTPUT=raw_data` (and `Y` axis) for a single
|
|
axis twice on a bed slinger printer with the accelerometer attached to the
|
|
toolhead the first time, and the accelerometer attached to the bed the
|
|
second time in order to detect axes cross-resonances and attempt to cancel
|
|
them with input shapers.
|
|
* Running `TEST_RESONANCES AXIS=Y OUTPUT=raw_data` twice on a bed slinger with
|
|
a glass bed and a magnetic surfaces (which is lighter) to find the input
|
|
shaper parameters that work well for any print surface configuration.
|
|
* Combining the resonance data from multiple test points.
|
|
* Combining the resonance data from 2 axis (e.g. on a bed slinger printer
|
|
to configure X-axis input_shaper from both X and Y axes resonances to
|
|
cancel vibrations of the *bed* in case the nozzle 'catches' a print when
|
|
moving in X axis direction).
|