klipper/docs/TMC_Drivers.md

558 lines
24 KiB
Markdown

# TMC drivers
This document provides information on using Trinamic stepper motor
drivers in SPI/UART mode on Klipper.
Klipper can also use Trinamic drivers in their "standalone mode".
However, when the drivers are in this mode, no special Klipper
configuration is needed and the advanced Klipper features discussed in
this document are not available.
In addition to this document, be sure to review the
[TMC driver config reference](Config_Reference.md#tmc-stepper-driver-configuration).
## Tuning motor current
A higher driver current increases positional accuracy and torque.
However, a higher current also increases the heat produced by the
stepper motor and the stepper motor driver. If the stepper motor
driver gets too hot it will disable itself and Klipper will report an
error. If the stepper motor gets too hot, it loses torque and
positional accuracy. (If it gets very hot it may also melt plastic
parts attached to it or near it.)
As a general tuning tip, prefer higher current values as long as the
stepper motor does not get too hot and the stepper motor driver does
not report warnings or errors. In general, it is okay for the stepper
motor to feel warm, but it should not become so hot that it is painful
to touch.
## Prefer to not specify a hold_current
If one configures a `hold_current` then the TMC driver can reduce
current to the stepper motor when it detects that the stepper is not
moving. However, changing motor current may itself introduce motor
movement. This may occur due to "detent forces" within the stepper
motor (the permanent magnet in the rotor pulls towards the iron teeth
in the stator) or due to external forces on the axis carriage.
Most stepper motors will not obtain a significant benefit to reducing
current during normal prints, because few printing moves will leave a
stepper motor idle for sufficiently long to activate the
`hold_current` feature. And, it is unlikely that one would want to
introduce subtle print artifacts to the few printing moves that do
leave a stepper idle sufficiently long.
If one wishes to reduce current to motors during print start routines,
then consider issuing
[SET_TMC_CURRENT](G-Codes.md#set_tmc_current) commands in a
[START_PRINT macro](Slicers.md#klipper-gcode_macro) to adjust the
current before and after normal printing moves.
Some printers with dedicated Z motors that are idle during normal
printing moves (no bed_mesh, no bed_tilt, no Z skew_correction, no
"vase mode" prints, etc.) may find that Z motors do run cooler with a
`hold_current`. If implementing this then be sure to take into account
this type of uncommanded Z axis movement during bed leveling, bed
probing, probe calibration, and similar. The `driver_TPOWERDOWN` and
`driver_IHOLDDELAY` should also be calibrated accordingly. If unsure,
prefer to not specify a `hold_current`.
## Setting "spreadCycle" vs "stealthChop" Mode
By default, Klipper places the TMC drivers in "spreadCycle" mode. If
the driver supports "stealthChop" then it can be enabled by adding
`stealthchop_threshold: 999999` to the TMC config section.
In general, spreadCycle mode provides greater torque and greater
positional accuracy than stealthChop mode. However, stealthChop mode
may produce significantly lower audible noise on some printers.
Tests comparing modes have shown an increased "positional lag" of
around 75% of a full-step during constant velocity moves when using
stealthChop mode (for example, on a printer with 40mm
rotation_distance and 200 steps_per_rotation, position deviation of
constant speed moves increased by ~0.150mm). However, this "delay in
obtaining the requested position" may not manifest as a significant
print defect and one may prefer the quieter behavior of stealthChop
mode.
It is recommended to always use "spreadCycle" mode (by not specifying
`stealthchop_threshold`) or to always use "stealthChop" mode (by
setting `stealthchop_threshold` to 999999). Unfortunately, the drivers
often produce poor and confusing results if the mode changes while the
motor is at a non-zero velocity.
## TMC interpolate setting introduces small position deviation
The TMC driver `interpolate` setting may reduce the audible noise of
printer movement at the cost of introducing a small systemic
positional error. This systemic positional error results from the
driver's delay in executing "steps" that Klipper sends it. During
constant velocity moves, this delay results in a positional error of
nearly half a configured microstep (more precisely, the error is half
a microstep distance minus a 512th of a full step distance). For
example, on an axis with a 40mm rotation_distance, 200
steps_per_rotation, and 16 microsteps, the systemic error introduced
during constant velocity moves is ~0.006mm.
For best positional accuracy consider using spreadCycle mode and
disable interpolation (set `interpolate: False` in the TMC driver
config). When configured this way, one may increase the `microstep`
setting to reduce audible noise during stepper movement. Typically, a
microstep setting of `64` or `128` will have similar audible noise as
interpolation, and do so without introducing a systemic positional
error.
If using stealthChop mode then the positional inaccuracy from
interpolation is small relative to the positional inaccuracy
introduced from stealthChop mode. Therefore tuning interpolation is
not considered useful when in stealthChop mode, and one can leave
interpolation in its default state.
## Sensorless Homing
Sensorless homing allows to home an axis without the need for a
physical limit switch. Instead, the carriage on the axis is moved into
the mechanical limit making the stepper motor lose steps. The stepper
driver senses the lost steps and indicates this to the controlling MCU
(Klipper) by toggling a pin. This information can be used by Klipper
as end stop for the axis.
This guide covers the setup of sensorless homing for the X axis of
your (cartesian) printer. However, it works the same with all other
axes (that require an end stop). You should configure and tune it for
one axis at a time.
### Limitations
Be sure that your mechanical components are able to handle the load of
the carriage bumping into the limit of the axis repeatedly. Especially
leadscrews might generate a lot of force. Homing a Z axis by bumping
the nozzle into the printing surface might not be a good idea. For
best results, verify that the axis carriage will make a firm contact
with the axis limit.
Further, sensorless homing might not be accurate enough for your
printer. While homing X and Y axes on a cartesian machine can work
well, homing the Z axis is generally not accurate enough and may
result in an inconsistent first layer height. Homing a delta printer
sensorless is not advisable due to missing accuracy.
Further, the stall detection of the stepper driver is dependent on the
mechanical load on the motor, the motor current and the motor
temperature (coil resistance).
Sensorless homing works best at medium motor speeds. For very slow
speeds (less than 10 RPM) the motor does not generate significant back
EMF and the TMC cannot reliably detect motor stalls. Further, at very
high speeds, the back EMF of the motor approaches the supply voltage
of the motor, so the TMC cannot detect stalls anymore. It is advised
to have a look in the datasheet of your specific TMCs. There you can
also find more details on limitations of this setup.
### Prerequisites
A few prerequisites are needed to use sensorless homing:
1. A stallGuard capable TMC stepper driver (tmc2130, tmc2209, tmc2660,
or tmc5160).
2. SPI / UART interface of the TMC driver wired to micro-controller
(stand-alone mode does not work).
3. The appropriate "DIAG" or "SG_TST" pin of TMC driver connected to
the micro-controller.
4. The steps in the [config checks](Config_checks.md) document must be
run to confirm the stepper motors are configured and working
properly.
### Tuning
The procedure described here has six major steps:
1. Choose a homing speed.
2. Configure the `printer.cfg` file to enable sensorless homing.
3. Find the stallguard setting with highest sensitivity that
successfully homes.
4. Find the stallguard setting with lowest sensitivity that
successfully homes with a single touch.
5. Update the `printer.cfg` with the desired stallguard setting.
6. Create or update `printer.cfg` macros to home consistently.
#### Choose homing speed
The homing speed is an important choice when performing sensorless
homing. It's desirable to use a slow homing speed so that the carriage
does not exert excessive force on the frame when making contact with
the end of the rail. However, the TMC drivers can't reliably detect a
stall at very slow speeds.
A good starting point for the homing speed is for the stepper motor to
make a full rotation every two seconds. For many axes this will be the
`rotation_distance` divided by two. For example:
```
[stepper_x]
rotation_distance: 40
homing_speed: 20
...
```
#### Configure printer.cfg for sensorless homing
The `homing_retract_dist` setting must be set to zero in the
`stepper_x` config section to disable the second homing move. The
second homing attempt does not add value when using sensorless homing,
it will not work reliably, and it will confuse the tuning process.
Be sure that a `hold_current` setting is not specified in the TMC
driver section of the config. (If a hold_current is set then after
contact is made, the motor stops while the carriage is pressed against
the end of the rail, and reducing the current while in that position
may cause the carriage to move - that results in poor performance and
will confuse the tuning process.)
It is necessary to configure the sensorless homing pins and to
configure initial "stallguard" settings. A tmc2209 example
configuration for an X axis might look like:
```
[tmc2209 stepper_x]
diag_pin: ^PA1 # Set to MCU pin connected to TMC DIAG pin
driver_SGTHRS: 255 # 255 is most sensitive value, 0 is least sensitive
...
[stepper_x]
endstop_pin: tmc2209_stepper_x:virtual_endstop
homing_retract_dist: 0
...
```
An example tmc2130 or tmc5160 config might look like:
```
[tmc2130 stepper_x]
diag1_pin: ^!PA1 # Pin connected to TMC DIAG1 pin (or use diag0_pin / DIAG0 pin)
driver_SGT: -64 # -64 is most sensitive value, 63 is least sensitive
...
[stepper_x]
endstop_pin: tmc2130_stepper_x:virtual_endstop
homing_retract_dist: 0
...
```
An example tmc2660 config might look like:
```
[tmc2660 stepper_x]
driver_SGT: -64 # -64 is most sensitive value, 63 is least sensitive
...
[stepper_x]
endstop_pin: ^PA1 # Pin connected to TMC SG_TST pin
homing_retract_dist: 0
...
```
The examples above only show settings specific to sensorless
homing. See the
[config reference](Config_Reference.md#tmc-stepper-driver-configuration)
for all the available options.
#### Find highest sensitivity that successfully homes
Place the carriage near the center of the rail. Use the SET_TMC_FIELD
command to set the highest sensitivity. For tmc2209:
```
SET_TMC_FIELD STEPPER=stepper_x FIELD=SGTHRS VALUE=255
```
For tmc2130, tmc5160, and tmc2660:
```
SET_TMC_FIELD STEPPER=stepper_x FIELD=sgt VALUE=-64
```
Then issue a `G28 X0` command and verify the axis does not move at
all. If the axis does move, then issue an `M112` to halt the printer -
something is not correct with the diag/sg_tst pin wiring or
configuration and it must be corrected before continuing.
Next, continually decrease the sensitivity of the `VALUE` setting and
run the `SET_TMC_FIELD` `G28 X0` commands again to find the highest
sensitivity that results in the carriage successfully moving all the
way to the endstop and halting. (For tmc2209 drivers this will be
decreasing SGTHRS, for other drivers it will be increasing sgt.) Be
sure to start each attempt with the carriage near the center of the
rail (if needed issue `M84` and then manually move the carriage to the
center). It should be possible to find the highest sensitivity that
homes reliably (settings with higher sensitivity result in small or no
movement). Note the found value as *maximum_sensitivity*. (If the
minimum possible sensitivity (SGTHRS=0 or sgt=63) is obtained without
any carriage movement then something is not correct with the
diag/sg_tst pin wiring or configuration and it must be corrected
before continuing.)
When searching for maximum_sensitivity, it may be convenient to jump
to different VALUE settings (so as to bisect the VALUE parameter). If
doing this then be prepared to issue an `M112` command to halt the
printer, as a setting with a very low sensitivity may cause the axis
to repeatedly "bang" into the end of the rail.
Be sure to wait a couple of seconds between each homing attempt. After
the TMC driver detects a stall it may take a little time for it to
clear its internal indicator and be capable of detecting another
stall.
During these tuning tests, if a `G28 X0` command does not move all the
way to the axis limit, then be careful with issuing any regular
movement commands (eg, `G1`). Klipper will not have a correct
understanding of the carriage position and a move command may cause
undesirable and confusing results.
#### Find lowest sensitivity that homes with one touch
When homing with the found *maximum_sensitivity* value, the axis
should move to the end of the rail and stop with a "single touch" -
that is, there should not be a "clicking" or "banging" sound. (If
there is a banging or clicking sound at maximum_sensitivity then the
homing_speed may be too low, the driver current may be too low, or
sensorless homing may not be a good choice for the axis.)
The next step is to again continually move the carriage to a position
near the center of the rail, decrease the sensitivity, and run the
`SET_TMC_FIELD` `G28 X0` commands - the goal is now to find the lowest
sensitivity that still results in the carriage successfully homing
with a "single touch". That is, it does not "bang" or "click" when
contacting the end of the rail. Note the found value as
*minimum_sensitivity*.
#### Update printer.cfg with sensitivity value
After finding *maximum_sensitivity* and *minimum_sensitivity*, use a
calculator to obtain the recommend sensitivity as
*minimum_sensitivity + (maximum_sensitivity - minimum_sensitivity)/3*.
The recommended sensitivity should be in the range between the minimum
and maximum, but slightly closer to the minimum. Round the final value
to the nearest integer value.
For tmc2209 set this in the config as `driver_SGTHRS`, for other TMC
drivers set this in the config as `driver_SGT`.
If the range between *maximum_sensitivity* and *minimum_sensitivity*
is small (eg, less than 5) then it may result in unstable homing. A
faster homing speed may increase the range and make the operation more
stable.
Note that if any change is made to driver current, homing speed, or a
notable change is made to the printer hardware, then it will be
necessary to run the tuning process again.
#### Using Macros when Homing
After sensorless homing completes the carriage will be pressed against
the end of the rail and the stepper will exert a force on the frame
until the carriage is moved away. It is a good idea to create a macro
to home the axis and immediately move the carriage away from the end
of the rail.
It is a good idea for the macro to pause at least 2 seconds prior to
starting sensorless homing (or otherwise ensure that there has been no
movement on the stepper for 2 seconds). Without a delay it is possible
for the driver's internal stall flag to still be set from a previous
move.
It can also be useful to have that macro set the driver current before
homing and set a new current after the carriage has moved away.
An example macro might look something like:
```
[gcode_macro SENSORLESS_HOME_X]
gcode:
{% set HOME_CUR = 0.700 %}
{% set driver_config = printer.configfile.settings['tmc2209 stepper_x'] %}
{% set RUN_CUR = driver_config.run_current %}
# Set current for sensorless homing
SET_TMC_CURRENT STEPPER=stepper_x CURRENT={HOME_CUR}
# Pause to ensure driver stall flag is clear
G4 P2000
# Home
G28 X0
# Move away
G90
G1 X5 F1200
# Set current during print
SET_TMC_CURRENT STEPPER=stepper_x CURRENT={RUN_CUR}
```
The resulting macro can be called from a
[homing_override config section](Config_Reference.md#homing_override)
or from a [START_PRINT macro](Slicers.md#klipper-gcode_macro).
Note that if the driver current during homing is changed, then the
tuning process should be run again.
### Tips for sensorless homing on CoreXY
It is possible to use sensorless homing on the X and Y carriages of a
CoreXY printer. Klipper uses the `[stepper_x]` stepper to detect
stalls when homing the X carriage and uses the `[stepper_y]` stepper
to detect stalls when homing the Y carriage.
Use the tuning guide described above to find the appropriate "stall
sensitivity" for each carriage, but be aware of the following
restrictions:
1. When using sensorless homing on CoreXY, make sure there is no
`hold_current` configured for either stepper.
2. While tuning, make sure both the X and Y carriages are near the
center of their rails before each home attempt.
3. After tuning is complete, when homing both X and Y, use macros to
ensure that one axis is homed first, then move that carriage away
from the axis limit, pause for at least 2 seconds, and then start
the homing of the other carriage. The move away from the axis
avoids homing one axis while the other is pressed against the axis
limit (which may skew the stall detection). The pause is necessary
to ensure the driver's stall flag is cleared prior to homing again.
## Querying and diagnosing driver settings
The `[DUMP_TMC command](G-Codes.md#dump_tmc) is a useful tool when
configuring and diagnosing the drivers. It will report all fields
configured by Klipper as well as all fields that can be queried from
the driver.
All of the reported fields are defined in the Trinamic datasheet for
each driver. These datasheets can be found on the
[Trinamic website](https://www.trinamic.com/). Obtain and review the
Trinamic datasheet for the driver to interpret the results of
DUMP_TMC.
## Configuring driver_XXX settings
Klipper supports configuring many low-level driver fields using
`driver_XXX` settings. The
[TMC driver config reference](Config_Reference.md#tmc-stepper-driver-configuration)
has the full list of fields available for each type of driver.
In addition, almost all fields can be modified at run-time using the
[SET_TMC_FIELD command](G-Codes.md#set_tmc_field).
Each of these fields is defined in the Trinamic datasheet for each
driver. These datasheets can be found on the
[Trinamic website](https://www.trinamic.com/).
Note that the Trinamic datasheets sometime use wording that can
confuse a high-level setting (such as "hysteresis end") with a
low-level field value (eg, "HEND"). In Klipper, `driver_XXX` and
SET_TMC_FIELD always set the low-level field value that is actually
written to the driver. So, for example, if the Trinamic datasheet
states that a value of 3 must be written to the HEND field to obtain a
"hysteresis end" of 0, then set `driver_HEND=3` to obtain the
high-level value of 0.
## Common Questions
### Can I use stealthChop mode on an extruder with pressure advance?
Many people successfully use "stealthChop" mode with Klipper's
pressure advance. Klipper implements
[smooth pressure advance](Kinematics.md#pressure-advance) which does
not introduce any instantaneous velocity changes.
However, "stealthChop" mode may produce lower motor torque and/or
produce higher motor heat. It may or may not be an adequate mode for
your particular printer.
### I keep getting "Unable to read tmc uart 'stepper_x' register IFCNT" errors?
This occurs when Klipper is unable to communicate with a tmc2208 or
tmc2209 driver.
Make sure that the motor power is enabled, as the stepper motor driver
generally needs motor power before it can communicate with the
micro-controller.
If this error occurs after flashing Klipper for the first time, then
the stepper driver may have been previously programmed in a state that
is not compatible with Klipper. To reset the state, remove all power
from the printer for several seconds (physically unplug both USB and
power plugs).
Otherwise, this error is typically the result of incorrect UART pin
wiring or an incorrect Klipper configuration of the UART pin settings.
### I keep getting "Unable to write tmc spi 'stepper_x' register ..." errors?
This occurs when Klipper is unable to communicate with a tmc2130 or
tmc5160 driver.
Make sure that the motor power is enabled, as the stepper motor driver
generally needs motor power before it can communicate with the
micro-controller.
Otherwise, this error is typically the result of incorrect SPI wiring,
an incorrect Klipper configuration of the SPI settings, or an
incomplete configuration of devices on an SPI bus.
Note that if the driver is on a shared SPI bus with multiple devices
then be sure to fully configure every device on that shared SPI bus in
Klipper. If a device on a shared SPI bus is not configured, then it
may incorrectly respond to commands not intended for it and corrupt
the communication to the intended device. If there is a device on a
shared SPI bus that can not be configured in Klipper, then use a
[static_digital_output config section](Config_Reference.md#static_digital_output)
to set the CS pin of the unused device high (so that it will not
attempt to use the SPI bus). The board's schematic is often a useful
reference for finding which devices are on an SPI bus and their
associated pins.
### Why did I get a "TMC reports error: ..." error?
This type of error indicates the TMC driver detected a problem and has
disabled itself. That is, the driver stopped holding its position and
ignored movement commands. If Klipper detects that an active driver
has disabled itself, it will transition the printer into a "shutdown"
state.
It's also possible that a **TMC reports error** shutdown occurs due to
SPI errors that prevent communication with the driver (on tmc2130,
tmc5160, or tmc2660). If this occurs, it's common for the reported
driver status to show `00000000` or `ffffffff` - for example: `TMC
reports error: DRV_STATUS: ffffffff ...` OR `TMC reports error:
READRSP@RDSEL2: 00000000 ...`. Such a failure may be due to an SPI
wiring problem or may be due to a self-reset or failure of the TMC
driver.
Some common errors and tips for diagnosing them:
#### TMC reports error: `... ot=1(OvertempError!)`
This indicates the motor driver disabled itself because it became too
hot. Typical solutions are to decrease the stepper motor current,
increase cooling on the stepper motor driver, and/or increase cooling
on the stepper motor.
#### TMC reports error: `... ShortToGND` OR `LowSideShort`
This indicates the driver has disabled itself because it detected very
high current passing through the driver. This may indicate a loose or
shorted wire to the stepper motor or within the stepper motor itself.
This error may also occur if using stealthChop mode and the TMC driver
is not able to accurately predict the mechanical load of the motor.
(If the driver makes a poor prediction then it may send too much
current through the motor and trigger its own over-current detection.)
To test this, disable stealthChop mode and check if the errors
continue to occur.
#### TMC reports error: `... reset=1(Reset)` OR `CS_ACTUAL=0(Reset?)` OR `SE=0(Reset?)`
This indicates that the driver has reset itself mid-print. This may be
due to voltage or wiring issues.
#### TMC reports error: `... uv_cp=1(Undervoltage!)`
This indicates the driver has detected a low-voltage event and has
disabled itself. This may be due to wiring or power supply issues.
### How do I tune spreadCycle/coolStep/etc. mode on my drivers?
The [Trinamic website](https://www.trinamic.com/) has guides on
configuring the drivers. These guides are often technical, low-level,
and may require specialized hardware. Regardless, they are the best
source of information.