# Support for I2C based LM75/LM75A temperature sensors
#
# Copyright (C) 2020 Boleslaw Ciesielski <combolek@users.noreply.github.com>
#
# This file may be distributed under the terms of the GNU GPLv3 license.
import logging
from . import bus
LM75_CHIP_ADDR = 0x48
LM75_I2C_SPEED = 100000
LM75_REGS = {
'TEMP' : 0x00,
'CONF' : 0x01,
'THYST' : 0x02,
'TOS' : 0x03,
'PRODID' : 0x07 # TI LM75A chips only?
}
LM75_REPORT_TIME = .8
# Temperature can be sampled at any time but the read aborts
# the current conversion. Conversion time is 300ms so make
# sure not to read too often.
LM75_MIN_REPORT_TIME = .5
class LM75:
def __init__(self, config):
self.printer = config.get_printer()
self.name = config.get_name().split()[-1]
self.reactor = self.printer.get_reactor()
self.i2c = bus.MCU_I2C_from_config(
config,
default_addr=LM75_CHIP_ADDR,
default_speed=LM75_I2C_SPEED
)
self.mcu = self.i2c.get_mcu()
self.report_time = config.getint(
'lm75_report_time',
LM75_REPORT_TIME,
minval=LM75_MIN_REPORT_TIME
)
self.temp = 0.0
self.sample_timer = self.reactor.register_timer(self._sample_lm75)
self.printer.add_object("lm75 " + self.name, self)
self.printer.register_event_handler("klippy:connect",
self.handle_connect)
def handle_connect(self):
self._init_lm75()
self.reactor.update_timer(self.sample_timer, self.reactor.NOW)
def setup_minmax(self, min_temp, max_temp):
pass
def setup_callback(self, cb):
self._callback = cb
def get_report_time_delta(self):
return self.report_time
def degrees_from_sample(self, x):
# The temp sample is encoded in the top 9 bits of a 16-bit
# value. Resolution is 0.5 degrees C.
return x[0] + (x[1] >> 7) * 0.5
def _init_lm75(self):
# Check and report the chip ID but ignore errors since many
# chips don't have it
try:
prodid = self.read_register('PRODID', 1)[0]
logging.info("lm75: Chip ID %#x" % prodid)
except:
pass
def _sample_lm75(self, eventtime):
try:
sample = self.read_register('TEMP', 2)
self.temp = self.degrees_from_sample(sample)
except Exception:
logging.exception("lm75: Error reading data")
self.temp = 0.0
return self.reactor.NEVER
measured_time = self.reactor.monotonic()
self._callback(self.mcu.estimated_print_time(measured_time), self.temp)
return measured_time + self.report_time
def read_register(self, reg_name, read_len):
# read a single register
regs = [LM75_REGS[reg_name]]
params = self.i2c.i2c_read(regs, read_len)
return bytearray(params['response'])
def write_register(self, reg_name, data):
if type(data) is not list:
data = [data]
reg = LM75_REGS[reg_name]
data.insert(0, reg)
self.i2c.i2c_write(data)
def get_status(self, eventtime):
return {
'temperature': self.temp,
}
def load_config(config):
# Register sensor
pheaters = config.get_printer().load_object(config, "heaters")
pheaters.add_sensor_factory("LM75", LM75)