Commit Graph

65 Commits

Author SHA1 Message Date
Kevin O'Connor f53897758d heater: Support max_power setting for heaters
Change the mcu PWM value from an integer (0-255) to a float (0. - 1.).
Add support for limiting the maximum power (as measured over a
sufficiently long duration) to a particular heater.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-03-03 20:00:16 -05:00
Kevin O'Connor 47f1d377f5 heater: Enforce min/max_temp in heater.set_temp()
Raise an error if the user requests a temperate outside the configured
min/max_temp range.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-02-21 10:48:42 -05:00
Kevin O'Connor f335045273 heater: Resend PWM values even if last value was zero
Continue to resend the pwm value even if the last value was zero -
this extends the debugging info.

Also, add the target temperature to the pwm debugging.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-01-12 15:13:41 -05:00
Kevin O'Connor 4ea091339e heater: Only create a soft PWM object for PID heaters
The "watermark" style heater only needs a digital_out pin - not a
software PWM pin.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-01-10 18:36:43 -05:00
Kevin O'Connor 4a71c7a2bd heater: Report last temperature in PWM debugging
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2017-01-10 12:36:51 -05:00
Kevin O'Connor 2f97b2d7c2 klippy: Add ConfigWrapper.getchoice method
Add helper function that ensures a config option is one of several
choices.  This helps ensure that a proper error is raised if an
invalid choice is made.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2016-11-30 21:19:44 -05:00
Kevin O'Connor ceb60ffcc6 mcu: Rename output_file_mode variable to is_fileoutput
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2016-11-29 21:54:40 -05:00
Kevin O'Connor d161d66741 mcu: Handle adc initialization entirely in mcu code
Don't expose the ADC initialization to the gcode and heater code -
instead, register a callback within the MCU_adc class and call it
directly from the MCU class after configuration completes.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2016-11-29 18:21:56 -05:00
Kevin O'Connor 3b5b895a10 heater: Do not require target temperature be above min_extrude_temp
Only disable the extruder if the last measured temperature is below
the minimum extrude temperature setting.  Verifying the target
temperature is not necessary, and it can incorrectly prevent some
valid moves.  It's not uncommon for scripts to retract filament
immiedietly after setting the extruder temperature to zero.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2016-11-08 09:22:43 -05:00
Kevin O'Connor 7f8a94ff48 heater: Make it possible to disable min_extrude_temp for testing
Allow a config file to specify 'min_extrude_temp: 0' to disable the
minimum extrude temperature test.  This makes it easier to perform
testing on the avr simulator.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2016-10-11 00:21:30 -04:00
Kevin O'Connor 9faa0fbd25 extruder: Support a minimum extrude temperature
Allow the config file to specify the minimum temperature for the
extruder and check for that temperature prior to moving the extruder
motor.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2016-09-30 21:36:51 -04:00
Kevin O'Connor 94272ed072 heater: Add "ATC Semitec 104GT-2" thermistor definition
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2016-09-15 12:16:08 -04:00
Kevin O'Connor 7b2f6f89f0 heater: Remove redundant float conversion
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2016-09-15 12:15:35 -04:00
Kevin O'Connor 11ecac626d mcu: Convert PWM and ADC objects to take mcu_time instead of clock
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2016-08-24 15:16:02 -04:00
Kevin O'Connor f582a36e4d Initial commit of source code.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2016-05-25 11:37:40 -04:00