Change the get_status command to get_clock. Don't report the shutdown
status in the new get_clock command.
The primary purpose of this change is to force the host code to report
a firmware version mismatch with older firmwares as recent changes
(namely the ordering of message block acks) have subtle
incompatibilities if different host/mcu code is used.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Normally, the MCU is restarted on a config change. However, that
should not be done automatically if the MCU is in a shutdown state.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
If the mcu is using a traditional serial port, then only send a new
message block if there is space available in the mcu receive buffer.
This should make it significantly less likely that high load on the
mcu will result in retransmits.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Send the ack after processing commands - this gives the host code more
information on serial buffer utilization.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
If a section name had mixed case it would cause an incorrect error
during the section/option config checking.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Add the ability to add a custom g-code command that in turn executes
one or more configured g-code commands.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
The recommended TOFF time in "standalone mode" according to the
tmc2130 is 4, so use that as the default.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
The extrude_factor and extruder position are specific to the current
extruder, so reset them to default values on a Tn command.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Use the new gcode.register_mux_command() so that SET_PRESSURE_ADVANCE
works correctly with multiple extruders.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
It's common to add commands that dispatch to a particular object
instance depending on the value of a command parameter. (For example,
the command "SET_SERVO SERVO=xyz" wants to be handled by the
particular "xyz" servo instance.) Add a register_mux_command() helper
to gcode.py make it easier to do this.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Move the common config reading and probe object lookup from the
bed_tilt.py and delta_calibrate.py code into the ProbePointsHelper
class.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Raise an error during config parsing if the position_endstop is not
between the position_min and position_max. This avoids a confusing
error message during homing.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
For some reason, Linux creates the pseudo tty with group writable
permissions, but not group readable. Use chmod to allow the device to
also be group readable.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
The step speed rounding and the cpu delay must be run after running
the endstop specific preparation code. Otherwise, a delay in the
home_prepare() code could undo those calculations. Specifically, this
could lead to errors on a multi-mcu setup when the Z is homed using a
virtual_z_offset and there is a delay in the activate_gcode section.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Don't return early on a command error - continue to process remaining
commands and pop commands from the queue.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Use the generic spi send/receive code on Linux. Update the replicape
code to use the updated command format.
Also, update the replicape code to turn off the stepper motors on a
shutdown event.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Improve the SPI message transmit system. Add support for bus speed
and bus mode. Add support for sending SPI messages on shutdown.
Signed-off-by: Petri Honkala <cruwaller@gmail.com>
Signed-off-by: Douglas Hammond <wizhippo@gmail.com>
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
In order to properly delay BACKGROUND_PRIORITY_CLOCK messages, they
must be 5ms beyond the minimum defined by MIN_REQTIME_DELTA. So, add
both MIN_REQTIME_DELTA and MIN_BACKGROUND_DELTA to the timing of these
messages.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
If the clock querying messages occur at a similar frequency to other
events on the micro-controller or host, then it's possible for the
load created by those other events to skew the clock synchronization.
In particular, the 500ms lcd screen update could resonate with the 1
second clock query. Use an unusual clock querying frequency to avoid
this issue.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Move the C code out of the main klippy/ directory and into its own
directory. This reduces the clutter in the main klippy directory.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Add a set_shutdown_speed() method so that the heater_fan code does not
need to peek into the fan object's internal members.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
The M206 command is confusing (it uses negative offsets) and isn't
very flexible. Add a new SET_GCODE_OFFSET command to make it easier
to add virtual offsets to gcode commands.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
The M206 command is confusing as positive values in that command
result in negative offsets to future g-code commands. Perform the
parameter negation in the M206 command instead of storing it that way
internally.
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>