Commit Graph

2247 Commits

Author SHA1 Message Date
Kevin O'Connor 945a84c0ea gcode: Use the same underlying error object for homing and gcode errors
Introduce a homing.CommandError and use that as the basis for both
gcode and EndstopError exceptions.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-06 10:08:58 -04:00
Kevin O'Connor 97adca18c4 docs: Update Delta_Calibrate.md with probe location bias info
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-06 10:08:58 -04:00
Kevin O'Connor e061029b3a docs: Update Probe_Calibrate.md with information on common probe errors
Add a section describing PROBE_ACCURACY, describing probe location
bias, and describing probe temperature bias.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-06 10:08:58 -04:00
Kevin O'Connor 15011012e5 probe: Simplify ProbePointsHelper start and end tracking
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-06 10:08:58 -04:00
Kevin O'Connor bbc8637ed6 probe: Be sure to call gcode.reset_last_position() after any manual move
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-06 10:08:58 -04:00
Kevin O'Connor 74cc005ff3 probe: Unify mean and median code between run_probe() and PROBE_ACCURACY
Factor out _calc_mean() and _calc_median() functions and call from
both run_probe() and cmd_PROBE_ACCURACY().

This also fixes a subtle error in the run_probe() median function - on
some kinematics the x and y position can change on a z move so the x
and y should be taken from the z probe values actually used.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-06 10:08:58 -04:00
Kevin O'Connor 2b8dca5dbf probe: Move multi-sampling capability from ProbePointsHelper to Probe
This changes the config file so that the configuration of
multi-samples is now done in the [probe] (and [bltouch]) section
instead of the various delta, bed_mesh, z_tilt, etc. config sections.

With this change, PROBE and PROBE_CALIBRATE commands now also utilize
multi-sampling.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-06 10:08:58 -04:00
Len Trigg 5989f7a8a6 firmware_retraction: Implementation of tuneable G10/G11 firmware retraction (#1617)
This supports getting and setting of retraction parameters without
having to restart klippy.

Signed-off-by: Len Trigg <lenbok@gmail.com>
2019-06-06 09:10:09 -04:00
Kevin O'Connor d065787afc gcode_macro: Add support "x in printer" to templates
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-04 12:41:28 -04:00
Kevin O'Connor 1c09a0935f idle_timeout: Add a get_status() method
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-04 12:35:50 -04:00
Kevin O'Connor 0bb714edd7 menu: Remove customized get_status overrides
Now that the extruder, display, heater_fan, output_pin, and servo
classes have get_status() methods, it is no longer necessary to
override them in the menu code.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-04 11:55:40 -04:00
Janar Sööt df765b33dc display: add get_status method
Signed-off-by: Janar Sööt <janar.soot@gmail.com>
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-04 11:51:46 -04:00
Janar Sööt 9155886c21 extruder: add get_status method
Signed-off-by: Janar Sööt <janar.soot@gmail.com>
2019-06-04 11:44:57 -04:00
Janar Sööt 94f5fb3553 servo: add get_status method
Signed-off-by: Janar Sööt <janar.soot@gmail.com>
2019-06-04 11:44:50 -04:00
Janar Sööt efecc96427 output_pin: add get_status method
Signed-off-by: Janar Sööt <janar.soot@gmail.com>
2019-06-04 11:44:35 -04:00
Janar Sööt e519ab2031 heater_fan: add get_status method
Signed-off-by: Janar Sööt <janar.soot@gmail.com>
2019-06-04 11:43:34 -04:00
Kevin O'Connor 3f96c0abd8 docs: Minor wording change to Command_Templates.md
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-04 10:39:43 -04:00
Kevin O'Connor 962c48ecf7 docs: Fix github pages "liquid" rendering of Command_Templates.md
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-04 10:31:03 -04:00
Kevin O'Connor 94c1ad7241 docs: Add an initial Command_Templates.md document
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-04 09:50:30 -04:00
Kevin O'Connor 52e7e52119 test: Add a macros.test test case for testing gcode_macro
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-04 09:50:30 -04:00
Kevin O'Connor a68f577adf gcode_macro: Add support for SET_GCODE_VARIABLE command
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-04 09:50:30 -04:00
Kevin O'Connor 6e88320d62 gcode: "gcode_position" and toolhead "position" as get_status() named tuple
Add "gcode_position" named tuple to gcode.get_status(). Add a
"position" named tuple to toolhead.get_status().

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-04 09:50:30 -04:00
Kevin O'Connor 4ccc218b06 gcode: Add action_x() callables to get_status()
Add action_respond_info(), action_respond_error(), and
action_emergency_stop() callables to the get_status() return
dictionary.  This allows gcode macros to directly invoke these
actions.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-04 09:50:30 -04:00
Kevin O'Connor ac8f6dfe20 gcode_macro: Rename "status" helper to "printer"
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-04 09:50:30 -04:00
Arksine a238ec6f98 idle_timeout: Add SET_IDLE_TIMEOUT gcode
Signed-off-by:  Eric Callahan <arksine.code@gmail.com>
2019-06-04 09:46:26 -04:00
Kevin O'Connor fe1c57b098 bed_screws: Be sure to call gcode.reset_last_position() after any manual move
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-03 13:43:49 -04:00
Arksine 05a04d5d3d pause_resume: Use Octoprint's "paused" and "resumed" action commands.
These action commands prevent Octoprint from sending extra gcodes that can interfere with Klipper's pause/resume control.

Signed-off-by:  Eric Callahan <arksine.code@gmail.com>
2019-06-02 19:19:32 -04:00
Arksine ca8233e6d5 pause_resume: use new save/restore gcodes to handle state
Signed-off-by:  Eric Callahan <arksine.code@gmail.com>
2019-06-02 19:19:32 -04:00
Kevin O'Connor 89650a1e60 adc_temperature: Minor comment update
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-02 17:12:55 -04:00
Artem Belevich 72100bc1f2 tmc2130: Check field name validity. (#1697)
This avoids crashing Klipper if user entered invalid field name.

Signed-off-by: Artem Belevich <artemb@gmail.com>
2019-06-02 11:41:15 -04:00
Kevin O'Connor 3910a44cc9 atsam: Add support for "timer" controlled hardware pwm pins
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-02 10:59:33 -04:00
Kevin O'Connor f96239019a mcu: Support a start value for soft pwm pins
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-02 10:59:33 -04:00
Kevin O'Connor 3e1c42da80 thermistor: Add support for printers with an "inline_resistor"
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-02 10:59:23 -04:00
Kevin O'Connor e2e4a5d4e6 atsamd: Add build support for SAMD21E15 chip
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-06-01 13:43:37 -04:00
Kevin O'Connor 1a8bd750fc logextract: Update for absolutecoord -> absolute_coord change
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-31 11:13:22 -04:00
Kevin O'Connor 7f04dc46d0 config: Update M600 in sample-macros.cfg to use SAVE_GCODE_STATE
Save and restore state in the example M600 macro.  Also, add
pause_resume config section.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-31 10:29:09 -04:00
Kevin O'Connor a5f82612a0 config: Add START_PRINT and END_PRINT examples to sample-macros.cfg
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-31 10:27:42 -04:00
Kevin O'Connor 8f5277c36a config: Formatting changes to sample-macros.cfg
Reformat some of the comments.  Add section headers.  Don't comment
out the config sections (so that it is more clear what needs to be
copied to the main config).

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-31 10:27:38 -04:00
Kevin O'Connor 02eeb72713 manual_probe: Verify no XY moves since start of manual probe
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-31 10:24:52 -04:00
Kevin O'Connor c54b8da530 gcode: Add support for SAVE_GCODE_STATE and RESTORE_GCODE_STATE commands
Add commands to save and restore the current g-code state.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-31 10:23:56 -04:00
Kevin O'Connor 9e7ef3cf89 atsamd: Reduce the compile size of the hard_pwm pin list
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-30 14:05:31 -04:00
Kevin O'Connor 6903ab87ca tmc2130: Add support for two's complement signed fields to FieldHelper
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-29 09:33:51 -04:00
Kevin O'Connor 2cff3291c0 gcode: Rename absolutecoord/extrude to absolute_coord/_extrude
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-26 21:00:15 -04:00
Kevin O'Connor 862b97ce8f gcode: Fix SET_GCODE_OFFSET MOVE_SPEED parameter
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-26 20:04:50 -04:00
Kevin O'Connor 423bbada84 gcode: Minor code change to M206 to make the math similar to SET_GCODE_OFFSET
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-26 12:37:14 -04:00
Kevin O'Connor d6b69938ab gcode: Don't apply the SET_GCODE_OFFSET to the next g-code command
The SET_GCODE_OFFSET command could cause unwanted behavior when an
offset is applied to the following g-code command.  (In particular,
when the following command is an extrude only move - as in
issue #1289.)

Don't apply the offset immediately.  Instead, add support for a MOVE=1
parameter which will schedule a move to apply the given offset.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-26 11:19:15 -04:00
Kevin O'Connor 500f37821d docs: Improve bltouch v3 documentation
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-26 11:09:32 -04:00
Kevin O'Connor 7702cc2972 bltouch: Update command timing
Prior to the BLTouch v3, the recommended command times were 700us
(pin_down), 1200us (touch_mode), 1500us (pin_up), 1800us (self_test),
and 2200us (reset).  However, the recommended Marlin timing (via servo
"angles") was 647.111, 1162.667, 1472, 1781.333, and 2193.778us.

As of the BLTouch v3, the recommended times are now 650, 1165, 1475,
1780, and 2190us.  The v3 continues to recommended Marlin timings of
647.111, 1162.667, 1472, 1781.333, and 2193.778us.

Update Klipper to use the new BL-Touch v3 recommended timing.  The new
timings are required for the BL-Touch v3 and they are closer to what
the Marlin firmware has historically used.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-26 11:09:32 -04:00
Kevin O'Connor 8532e2123e gpiocmds: Specify soft pwm duration in clock ticks
Improve the precision of soft pwm pulses by allowing the host to
directly specify the clock duration of the pulse.  This improvement in
precision may be noticeable when controller servos (and bltouch).

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-26 11:09:32 -04:00
Kevin O'Connor 8cd8cb492e buttons: Minor code movement
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
2019-05-26 00:18:48 -04:00