probe: Allow overriding horizontal_move_z on gcode
Signed-off-by: Lasse Dalegaard <dalegaard@gmail.com>
This commit is contained in:
parent
5a69d0f857
commit
ca6e5fe514
|
@ -146,14 +146,15 @@ The following commands are available when the
|
|||
(also see the [bed mesh guide](Bed_Mesh.md)).
|
||||
|
||||
#### BED_MESH_CALIBRATE
|
||||
`BED_MESH_CALIBRATE [METHOD=manual] [<probe_parameter>=<value>]
|
||||
[<mesh_parameter>=<value>]`: This command probes the bed using
|
||||
generated points specified by the parameters in the config. After
|
||||
probing, a mesh is generated and z-movement is adjusted according to
|
||||
the mesh. See the PROBE command for details on the optional probe
|
||||
parameters. If METHOD=manual is specified then the manual probing tool
|
||||
is activated - see the MANUAL_PROBE command above for details on the
|
||||
additional commands available while this tool is active.
|
||||
`BED_MESH_CALIBRATE [METHOD=manual] [HORIZONTAL_MOVE_Z=<value>]
|
||||
[<probe_parameter>=<value>] [<mesh_parameter>=<value>]`: This command probes
|
||||
the bed using generated points specified by the parameters in the config. After
|
||||
probing, a mesh is generated and z-movement is adjusted according to the mesh.
|
||||
See the PROBE command for details on the optional probe parameters. If
|
||||
METHOD=manual is specified then the manual probing tool is activated - see the
|
||||
MANUAL_PROBE command above for details on the additional commands available
|
||||
while this tool is active. The optional `HORIZONTAL_MOVE_Z` value overrides the
|
||||
`horizontal_move_z` option specified in the config file.
|
||||
|
||||
#### BED_MESH_OUTPUT
|
||||
`BED_MESH_OUTPUT PGP=[<0:1>]`: This command outputs the current probed
|
||||
|
@ -207,13 +208,14 @@ The following commands are available when the
|
|||
[bed_tilt config section](Config_Reference.md#bed_tilt) is enabled.
|
||||
|
||||
#### BED_TILT_CALIBRATE
|
||||
`BED_TILT_CALIBRATE [METHOD=manual] [<probe_parameter>=<value>]`: This
|
||||
command will probe the points specified in the config and then
|
||||
recommend updated x and y tilt adjustments. See the PROBE command for
|
||||
details on the optional probe parameters. If METHOD=manual is
|
||||
specified then the manual probing tool is activated - see the
|
||||
MANUAL_PROBE command above for details on the additional commands
|
||||
available while this tool is active.
|
||||
`BED_TILT_CALIBRATE [METHOD=manual] [HORIZONTAL_MOVE_Z=<value>]
|
||||
[<probe_parameter>=<value>]`: This command will probe the points specified in
|
||||
the config and then recommend updated x and y tilt adjustments. See the PROBE
|
||||
command for details on the optional probe parameters. If METHOD=manual is
|
||||
specified then the manual probing tool is activated - see the MANUAL_PROBE
|
||||
command above for details on the additional commands available while this tool
|
||||
is active. The optional `HORIZONTAL_MOVE_Z` value overrides the
|
||||
`horizontal_move_z` option specified in the config file.
|
||||
|
||||
### [bltouch]
|
||||
|
||||
|
@ -262,13 +264,14 @@ The following commands are available when the
|
|||
is enabled (also see the [delta calibrate guide](Delta_Calibrate.md)).
|
||||
|
||||
#### DELTA_CALIBRATE
|
||||
`DELTA_CALIBRATE [METHOD=manual] [<probe_parameter>=<value>]`: This
|
||||
command will probe seven points on the bed and recommend updated
|
||||
endstop positions, tower angles, and radius. See the PROBE command for
|
||||
details on the optional probe parameters. If METHOD=manual is
|
||||
specified then the manual probing tool is activated - see the
|
||||
MANUAL_PROBE command above for details on the additional commands
|
||||
available while this tool is active.
|
||||
`DELTA_CALIBRATE [METHOD=manual] [HORIZONTAL_MOVE_Z=<value>]
|
||||
[<probe_parameter>=<value>]`: This command will probe seven points on the bed
|
||||
and recommend updated endstop positions, tower angles, and radius. See the
|
||||
PROBE command for details on the optional probe parameters. If METHOD=manual is
|
||||
specified then the manual probing tool is activated - see the MANUAL_PROBE
|
||||
command above for details on the additional commands available while this tool
|
||||
is active. The optional `HORIZONTAL_MOVE_Z` value overrides the
|
||||
`horizontal_move_z` option specified in the config file.
|
||||
|
||||
#### DELTA_ANALYZE
|
||||
`DELTA_ANALYZE`: This command is used during enhanced delta
|
||||
|
@ -1078,16 +1081,17 @@ is enabled (also see the
|
|||
|
||||
#### SCREWS_TILT_CALCULATE
|
||||
`SCREWS_TILT_CALCULATE [DIRECTION=CW|CCW] [MAX_DEVIATION=<value>]
|
||||
[<probe_parameter>=<value>]`: This command will invoke the bed screws
|
||||
adjustment tool. It will command the nozzle to different locations (as
|
||||
defined in the config file) probing the z height and calculate the
|
||||
number of knob turns to adjust the bed level. If DIRECTION is
|
||||
specified, the knob turns will all be in the same direction, clockwise
|
||||
(CW) or counterclockwise (CCW). See the PROBE command for details on
|
||||
the optional probe parameters. IMPORTANT: You MUST always do a G28
|
||||
before using this command. If MAX_DEVIATION is specified, the command
|
||||
will raise a gcode error if any difference in the screw height
|
||||
relative to the base screw height is greater than the value provided.
|
||||
[HORIZONTAL_MOVE_Z=<value>] [<probe_parameter>=<value>]`: This command will
|
||||
invoke the bed screws adjustment tool. It will command the nozzle to different
|
||||
locations (as defined in the config file) probing the z height and calculate
|
||||
the number of knob turns to adjust the bed level. If DIRECTION is specified,
|
||||
the knob turns will all be in the same direction, clockwise (CW) or
|
||||
counterclockwise (CCW). See the PROBE command for details on the optional probe
|
||||
parameters. IMPORTANT: You MUST always do a G28 before using this command. If
|
||||
MAX_DEVIATION is specified, the command will raise a gcode error if any
|
||||
difference in the screw height relative to the base screw height is greater
|
||||
than the value provided. The optional `HORIZONTAL_MOVE_Z` value overrides the
|
||||
`horizontal_move_z` option specified in the config file.
|
||||
|
||||
### [sdcard_loop]
|
||||
|
||||
|
@ -1329,7 +1333,8 @@ The following commands are available when the
|
|||
[z_tilt config section](Config_Reference.md#z_tilt) is enabled.
|
||||
|
||||
#### Z_TILT_ADJUST
|
||||
`Z_TILT_ADJUST [<probe_parameter>=<value>]`: This command will probe
|
||||
the points specified in the config and then make independent
|
||||
adjustments to each Z stepper to compensate for tilt. See the PROBE
|
||||
command for details on the optional probe parameters.
|
||||
`Z_TILT_ADJUST [HORIZONTAL_MOVE_Z=<value>] [<probe_parameter>=<value>]`: This
|
||||
command will probe the points specified in the config and then make independent
|
||||
adjustments to each Z stepper to compensate for tilt. See the PROBE command for
|
||||
details on the optional probe parameters. The optional `HORIZONTAL_MOVE_Z`
|
||||
value overrides the `horizontal_move_z` option specified in the config file.
|
||||
|
|
|
@ -362,7 +362,8 @@ class ProbePointsHelper:
|
|||
if default_points is None or config.get('points', None) is not None:
|
||||
self.probe_points = config.getlists('points', seps=(',', '\n'),
|
||||
parser=float, count=2)
|
||||
self.horizontal_move_z = config.getfloat('horizontal_move_z', 5.)
|
||||
def_move_z = config.getfloat('horizontal_move_z', 5.)
|
||||
self.default_horizontal_move_z = def_move_z
|
||||
self.speed = config.getfloat('speed', 50., above=0.)
|
||||
self.use_offsets = False
|
||||
# Internal probing state
|
||||
|
@ -408,6 +409,9 @@ class ProbePointsHelper:
|
|||
probe = self.printer.lookup_object('probe', None)
|
||||
method = gcmd.get('METHOD', 'automatic').lower()
|
||||
self.results = []
|
||||
def_move_z = self.default_horizontal_move_z
|
||||
self.horizontal_move_z = gcmd.get_float('HORIZONTAL_MOVE_Z',
|
||||
def_move_z)
|
||||
if probe is None or method != 'automatic':
|
||||
# Manual probe
|
||||
self.lift_speed = self.speed
|
||||
|
|
Loading…