docs: Try to be more clear that the "paper test" steps need to be run
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
7792b0f2bb
commit
c77285287b
|
@ -42,13 +42,14 @@ There are two ways to perform the probing - manual probing
|
||||||
(`DELTA_CALIBRATE`). Automatic probing utilizes a hardware device
|
(`DELTA_CALIBRATE`). Automatic probing utilizes a hardware device
|
||||||
capable of triggering when the toolhead is at a set distance from the
|
capable of triggering when the toolhead is at a set distance from the
|
||||||
bed. The manual probing method will move the head near the bed and
|
bed. The manual probing method will move the head near the bed and
|
||||||
then wait for the user to follow the
|
then wait for the user to follow the steps described at
|
||||||
["paper test"](Bed_Level.md#the-paper-test) steps. It is recommended
|
["the paper test"](Bed_Level.md#the-paper-test) to determine the
|
||||||
to use manual probing for delta calibration. A number of common
|
actual distance between the nozzle and bed at the given location. It
|
||||||
printer kits come with probes that are not sufficiently accurate
|
is recommended to use manual probing for delta calibration. A number
|
||||||
(specifically, small differences in arm length can cause effector tilt
|
of common printer kits come with probes that are not sufficiently
|
||||||
which can skew an automatic probe). Manual probing only takes a few
|
accurate (specifically, small differences in arm length can cause
|
||||||
minutes and it eliminates error introduced by the probe.
|
effector tilt which can skew an automatic probe). Manual probing only
|
||||||
|
takes a few minutes and it eliminates error introduced by the probe.
|
||||||
|
|
||||||
To perform the basic probe, make sure the config has a
|
To perform the basic probe, make sure the config has a
|
||||||
[delta_calibrate] section defined and run:
|
[delta_calibrate] section defined and run:
|
||||||
|
|
|
@ -17,9 +17,11 @@ terminal tab, and run:
|
||||||
```
|
```
|
||||||
Z_ENDSTOP_CALIBRATE
|
Z_ENDSTOP_CALIBRATE
|
||||||
```
|
```
|
||||||
Then perform the ["paper test"](Bed_Level.md#the-paper-test) steps to
|
Then follow the steps described at
|
||||||
determine the actual height at the given position. One can then
|
["the paper test"](Bed_Level.md#the-paper-test) to determine the
|
||||||
`ACCEPT` the position and save the results to the config file with:
|
actual distance between the nozzle and bed at the given location. Once
|
||||||
|
those steps are complete one can `ACCEPT` the position and save the
|
||||||
|
results to the config file with:
|
||||||
```
|
```
|
||||||
SAVE_CONFIG
|
SAVE_CONFIG
|
||||||
```
|
```
|
||||||
|
|
|
@ -53,14 +53,15 @@ tool.
|
||||||
|
|
||||||
This tool will perform an automatic probe, then lift the head, move
|
This tool will perform an automatic probe, then lift the head, move
|
||||||
the nozzle over the location of the probe point, and start the manual
|
the nozzle over the location of the probe point, and start the manual
|
||||||
probe tool. Once the manual probe tool starts, perform the
|
probe tool. If the nozzle does not move to a position above the
|
||||||
["paper test"](Bed_Level.md#the-paper-test) to determine the actual
|
automatic probe point, then `ABORT` the manual probe tool and perform
|
||||||
nozzle height at the given point.
|
the XY probe offset calibration described above.
|
||||||
|
|
||||||
If the nozzle does not move to a position above the probe point, then
|
Once the manual probe tool starts, follow the steps described at
|
||||||
`ABORT` the manual probe tool and perform the XY probe offset
|
["the paper test"](Bed_Level.md#the-paper-test)) to determine the
|
||||||
calibration described above.
|
actual distance between the nozzle and bed at the given location. Once
|
||||||
|
those steps are complete one can `ACCEPT` the position and save the
|
||||||
After completing the "paper test", use the `ACCEPT` command to
|
results to the config file with:
|
||||||
accept the current Z height and then use the `SAVE_CONFIG` command to
|
```
|
||||||
save the given probe z_offset to the config file.
|
SAVE_CONFIG
|
||||||
|
```
|
||||||
|
|