sx1509: Relax restrictions on SX1509 pins (#836)
This allows SX1509 pins to be used as temperature fans and heater fans. Heaters are still disallowed. Signed-off-by: Florian Heilmann <Florian.Heilmann@gmx.net>
This commit is contained in:
parent
3328ade194
commit
b98e12c19a
|
@ -126,11 +126,11 @@ class SX1509_digital_out(object):
|
|||
def setup_max_duration(self, max_duration):
|
||||
self._max_duration = max_duration
|
||||
def setup_start_value(self, start_value, shutdown_value, is_static=False):
|
||||
if is_static or shutdown_value:
|
||||
raise pins.error("SX1509 Pins should not be declared static or have a shutdown value")
|
||||
if is_static and start_value != shutdown_value:
|
||||
raise pins.error("Static pin can not have shutdown value")
|
||||
self._start_value = (not not start_value) ^ self._invert
|
||||
self._shutdown_value = self._invert
|
||||
self._is_static = False
|
||||
self._is_static = is_static
|
||||
# We need to set the start value here so the register is
|
||||
# updated before the SX1509 class writes it.
|
||||
if self._start_value:
|
||||
|
@ -190,14 +190,14 @@ class SX1509_pwm(object):
|
|||
self._cycle_time = cycle_time
|
||||
self._hardware_pwm = hardware_pwm
|
||||
def setup_start_value(self, start_value, shutdown_value, is_static=False):
|
||||
if is_static or shutdown_value:
|
||||
raise pins.error("SX1509 Pins should not be declared static or have a shutdown value")
|
||||
if is_static and start_value != shutdown_value:
|
||||
raise pins.error("Static pin can not have shutdown value")
|
||||
if self._invert:
|
||||
start_value = 1. - start_value
|
||||
shutdown_value = 1. - shutdown_value
|
||||
self._start_value = max(0., min(1., start_value))
|
||||
self._shutdown_value = max(0., min(1., shutdown_value))
|
||||
self._is_static = False
|
||||
self._is_static = is_static
|
||||
def set_pwm(self, print_time, value):
|
||||
self._sx1509.set_register(self._i_on_reg, ~int(255 * value)
|
||||