Docs: resonance testing fixup (#3804)

Chip names are now correct for bed slingers.
Added some notes about testing with >1 chip

Signed-off-by: Jarad Olson <brotherdust@gmail.com>
This commit is contained in:
Jarad Olson 2021-01-24 08:22:18 -07:00 committed by GitHub
parent 1e2eb9a4de
commit b32166c8a0
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
1 changed files with 8 additions and 3 deletions

View File

@ -99,7 +99,12 @@ Measuring the resonances
## Checking the setup
Now you can test a connection. In Octoprint, run `ACCELEROMETER_QUERY`. You
Now you can test a connection.
- For "non bed-slingers" (e.g. one accelerometer), in Octoprint, enter `ACCELEROMETER_QUERY`
- For "bed-slingers" (e.g. more than one accelerometer), enter `ACCELEROMETER_QUERY CHIP=adxl345_x` where `adxl345_x` is the name of the chip as-entered (see: [bed-slinger](#bed-slinger-printers)).
In Octoprint, run `ACCELEROMETER_QUERY`. You
should see the current measurements from the accelerometer, including the
free-fall acceleration, e.g.
```
@ -215,8 +220,8 @@ cs_pin: rpi:None
cs_pin: ... # Printer board SPI chip select (CS) pin
[resonance_tester]
accel_chip_x: adxl345_x
accel_chip_y: adxl345_y
accel_chip_x: adxl345 adxl345_x
accel_chip_y: adxl345 adxl345_y
probe_points: ...
```