docs: document bed mesh "faulty_regions"
Signed-off-by: Eric Callahan <arksine.code@gmail.com>
This commit is contained in:
parent
60372fd0cf
commit
a93d09cdf4
|
@ -291,6 +291,56 @@ to the spot on the bed where Z endstop calibration was done. Note that
|
|||
when looking up the index using the log or BED_MESH_OUTPUT, you should use
|
||||
the coordinates listed under the "Probe" header to find the correct index.
|
||||
|
||||
### Faulty Regions
|
||||
|
||||
It is possible for some areas of a bed to report inaccurate results when
|
||||
probing due to a "fault" at specific locations. The best example of this
|
||||
are beds with series of integrated magnets used to retain removable steel
|
||||
sheets. The magnetic field at and around these magnets may cause an inductive
|
||||
probe to trigger at a distance higher or lower than it would otherwise,
|
||||
resulting in a mesh that does not accurately represent the surface at these
|
||||
locations. **Note: This should not be confused with probe location bias, which
|
||||
produces inaccurate results across the entire bed.**
|
||||
|
||||
The `faulty_region` options may be configured to compensate for this affect.
|
||||
If a generated point lies within a faulty region bed mesh will attempt to
|
||||
probe up to 4 points at the boundaries of this region. These probed values
|
||||
will be averaged and inserted in the mesh as the Z value at the generated
|
||||
(X, Y) coordinate.
|
||||
|
||||
```
|
||||
[bed_mesh]
|
||||
speed: 120
|
||||
horizontal_move_z: 5
|
||||
mesh_min: 35,6
|
||||
mesh_max: 240, 198
|
||||
probe_count: 5,3
|
||||
faulty_region_1_min: 130.0, 0.0
|
||||
faulty_region_1_max: 145.0, 40.0
|
||||
faulty_region_2_min: 225.0, 0.0
|
||||
faulty_region_2_max: 250.0, 25.0
|
||||
faulty_region_3_min: 165.0, 95.0
|
||||
faulty_region_3_max: 205.0, 110.0
|
||||
faulty_region_4_min: 30.0, 170.0
|
||||
faulty_region_4_max: 45.0, 210.0
|
||||
```
|
||||
|
||||
- `faulty_region_{1...99}_min`\
|
||||
`faulty_region_{1..99}_max`\
|
||||
_Default Value: None (disabled)_\
|
||||
Faulty Regions are defined in a way similar to that of mesh itself, where
|
||||
minimum and maximum (X, Y) coordinates must be specified for each region.
|
||||
A faulty region may extend outside of a mesh, however the alternate points
|
||||
generated will always be within the mesh boundary. No two regions may
|
||||
overlap.
|
||||
|
||||
The image below illustrates how replacement points are generated when
|
||||
a generated point lies within a faulty region. The regions shown match those
|
||||
in the sample config above. The replacement points and their coordinates
|
||||
are identified in green.
|
||||
|
||||
![bedmesh_interpolated](img/bedmesh_faulty_regions.svg)
|
||||
|
||||
## Bed Mesh Gcodes
|
||||
|
||||
### Calibration
|
||||
|
|
|
@ -802,6 +802,11 @@ Visual Examples:
|
|||
# A point index in the mesh to reference all z values to. Enabling
|
||||
# this parameter produces a mesh relative to the probed z position
|
||||
# at the provided index.
|
||||
#faulty_region_1_min:
|
||||
#faulty_region_1_max:
|
||||
# Optional points that define a faulty region. See docs/Bed_Mesh.md
|
||||
# for details on faulty regions. Up to 99 faulty regions may be added.
|
||||
# By default no faulty regions are set.
|
||||
```
|
||||
|
||||
## [bed_tilt]
|
||||
|
|