docs: Update pressure advance doc to note it only impacts the extruder
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
3d7e8fa5ec
commit
a7c8476e98
|
@ -133,3 +133,11 @@ Important Notes
|
||||||
(filament pulled out of the nozzle due to the stickiness of the
|
(filament pulled out of the nozzle due to the stickiness of the
|
||||||
plastic). It is recommended to disable the slicer's "z-lift on
|
plastic). It is recommended to disable the slicer's "z-lift on
|
||||||
retract" option.
|
retract" option.
|
||||||
|
|
||||||
|
* Configuring pressure advance results in extra extruder movement
|
||||||
|
during move acceleration and deceleration. That extra movement is
|
||||||
|
not further constrained by any other other configuration parameter.
|
||||||
|
The pressure advance settings only impact extruder movement; they do
|
||||||
|
not alter toolhead XYZ movement or look-ahead calculations. A change
|
||||||
|
in pressure advance will not change the path or timing of the
|
||||||
|
toolhead nor will it change the overall printing time.
|
||||||
|
|
Loading…