spi_temperature: Eliminate get_configs() callback
Those chips that require an spi init sequence can generate the message directly in the chip specific class. Also, don't send an spi init message for chips that are read-only. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
c52c398ae8
commit
a084c38b41
|
@ -24,7 +24,7 @@ class error(Exception):
|
|||
|
||||
class SensorBase:
|
||||
error = error
|
||||
def __init__(self, config, chip_type):
|
||||
def __init__(self, config, chip_type, config_cmd=None):
|
||||
self._callback = None
|
||||
self.min_sample_value = self.max_sample_value = 0
|
||||
self._report_clock = 0
|
||||
|
@ -41,9 +41,10 @@ class SensorBase:
|
|||
"config_spi oid=%u bus=%u pin=%s"
|
||||
" mode=%u rate=%u shutdown_msg=" % (
|
||||
spi_oid, 0, pin, spi_mode, spi_speed))
|
||||
config_cmd = "".join("%02x" % b for b in self.get_configs())
|
||||
mcu.add_config_cmd("spi_send oid=%u data=%s" % (
|
||||
spi_oid, config_cmd), is_init=True)
|
||||
if config_cmd is not None:
|
||||
config_cmd = "".join("%02x" % b for b in config_cmd)
|
||||
mcu.add_config_cmd("spi_send oid=%u data=%s" % (
|
||||
spi_oid, config_cmd), is_init=True)
|
||||
# Reader chip configuration
|
||||
self.oid = oid = mcu.create_oid()
|
||||
mcu.add_config_cmd(
|
||||
|
@ -134,27 +135,8 @@ MAX31856_MULT = 0.0078125
|
|||
|
||||
class MAX31856(SensorBase):
|
||||
def __init__(self, config):
|
||||
types = {
|
||||
"B" : 0b0000,
|
||||
"E" : 0b0001,
|
||||
"J" : 0b0010,
|
||||
"K" : 0b0011,
|
||||
"N" : 0b0100,
|
||||
"R" : 0b0101,
|
||||
"S" : 0b0110,
|
||||
"T" : 0b0111,
|
||||
}
|
||||
self.tc_type = config.getchoice('tc_type', types, default="K")
|
||||
self.use_50Hz_filter = config.getboolean('tc_use_50Hz_filter', False)
|
||||
averages = {
|
||||
"1" : MAX31856_CR1_AVGSEL1,
|
||||
"2" : MAX31856_CR1_AVGSEL2,
|
||||
"4" : MAX31856_CR1_AVGSEL4,
|
||||
"8" : MAX31856_CR1_AVGSEL8,
|
||||
"16" : MAX31856_CR1_AVGSEL16
|
||||
}
|
||||
self.average_count = config.getchoice('tc_averaging_count', averages, "1")
|
||||
SensorBase.__init__(self, config, TS_CHIP_MAX31856)
|
||||
SensorBase.__init__(self, config, TS_CHIP_MAX31856,
|
||||
self.build_spi_init(config))
|
||||
def calc_temp(self, adc, fault):
|
||||
if fault & MAX31856_FAULT_CJRANGE:
|
||||
raise self.error("Max31856: Cold Junction Range Fault")
|
||||
|
@ -182,16 +164,33 @@ class MAX31856(SensorBase):
|
|||
adc = int( ( temp / MAX31856_MULT ) + 0.5 ) # convert to ADC value
|
||||
adc = adc << MAX31856_SCALE
|
||||
return adc
|
||||
def get_configs(self):
|
||||
def build_spi_init(self, config):
|
||||
cmds = []
|
||||
value = MAX31856_CR0_AUTOCONVERT
|
||||
if self.use_50Hz_filter:
|
||||
if config.getboolean('tc_use_50Hz_filter', False):
|
||||
value |= MAX31856_CR0_FILT50HZ
|
||||
cmds.append(0x80 + MAX31856_CR0_REG)
|
||||
cmds.append(value)
|
||||
|
||||
value = self.tc_type
|
||||
value |= self.average_count
|
||||
types = {
|
||||
"B" : 0b0000,
|
||||
"E" : 0b0001,
|
||||
"J" : 0b0010,
|
||||
"K" : 0b0011,
|
||||
"N" : 0b0100,
|
||||
"R" : 0b0101,
|
||||
"S" : 0b0110,
|
||||
"T" : 0b0111,
|
||||
}
|
||||
value = config.getchoice('tc_type', types, default="K")
|
||||
averages = {
|
||||
"1" : MAX31856_CR1_AVGSEL1,
|
||||
"2" : MAX31856_CR1_AVGSEL2,
|
||||
"4" : MAX31856_CR1_AVGSEL4,
|
||||
"8" : MAX31856_CR1_AVGSEL8,
|
||||
"16" : MAX31856_CR1_AVGSEL16
|
||||
}
|
||||
value |= config.getchoice('tc_averaging_count', averages, "1")
|
||||
cmds.append(0x80 + MAX31856_CR1_REG)
|
||||
cmds.append(value)
|
||||
|
||||
|
@ -229,8 +228,6 @@ class MAX31855(SensorBase):
|
|||
adc = int( ( temp / MAX31855_MULT ) + 0.5 ) # convert to ADC value
|
||||
adc = adc << MAX31855_SCALE
|
||||
return adc
|
||||
def get_configs(self):
|
||||
return []
|
||||
|
||||
|
||||
######################################################################
|
||||
|
@ -258,8 +255,6 @@ class MAX6675(SensorBase):
|
|||
adc = int( ( temp / MAX6675_MULT ) + 0.5 ) # convert to ADC value
|
||||
adc = adc << MAX6675_SCALE
|
||||
return adc
|
||||
def get_configs(self):
|
||||
return []
|
||||
|
||||
|
||||
######################################################################
|
||||
|
@ -298,9 +293,8 @@ class MAX31865(SensorBase):
|
|||
def __init__(self, config):
|
||||
self.rtd_nominal_r = config.getint('rtd_nominal_r', 100)
|
||||
self.reference_r = config.getfloat('rtd_reference_r', 430., above=0.)
|
||||
self.num_wires = config.getint('rtd_num_of_wires', 2)
|
||||
self.use_50Hz_filter = config.getboolean('rtd_use_50Hz_filter', False)
|
||||
SensorBase.__init__(self, config, TS_CHIP_MAX31865)
|
||||
SensorBase.__init__(self, config, TS_CHIP_MAX31865,
|
||||
self.build_spi_init(config))
|
||||
def calc_temp(self, adc, fault):
|
||||
if fault & 0x80:
|
||||
raise self.error("Max31865 RTD input is disconnected")
|
||||
|
@ -333,13 +327,13 @@ class MAX31865(SensorBase):
|
|||
adc = int( ( ( R_rtd * VAL_ADC_MAX ) / self.reference_r) + 0.5 )
|
||||
adc = adc << 1 # Add fault bit
|
||||
return adc
|
||||
def get_configs(self):
|
||||
def build_spi_init(self, config):
|
||||
value = (MAX31865_CONFIG_BIAS |
|
||||
MAX31865_CONFIG_MODEAUTO |
|
||||
MAX31865_CONFIG_FAULTCLEAR)
|
||||
if self.use_50Hz_filter:
|
||||
if config.getboolean('rtd_use_50Hz_filter', False):
|
||||
value |= MAX31865_CONFIG_FILT50HZ
|
||||
if self.num_wires == 3:
|
||||
if config.getint('rtd_num_of_wires', 2) == 3:
|
||||
value |= MAX31865_CONFIG_3WIRE
|
||||
cmd = 0x80 + MAX31865_CONFIG_REG
|
||||
return [cmd, value]
|
||||
|
|