uc1701: Add support for a reset line on SSD1306 displays
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
05bb5484b4
commit
96fdb6ef36
|
@ -1404,6 +1404,10 @@
|
|||
# mode. The parameters that start with "spi_" are optional and they
|
||||
# control the spi settings used to communicate with the chip. The
|
||||
# default is to use i2c mode for ssd1306 displays.
|
||||
#reset_pin:
|
||||
# A reset pin may be specified on ssd1306 displays. If it is not
|
||||
# specified then the hardware must have a pull-up on the
|
||||
# corresponding lcd line.
|
||||
#menu_root:
|
||||
# Entry point for menu, root menu container name. If this parameter
|
||||
# is not provided then default menu root is used. When provided
|
||||
|
|
|
@ -200,10 +200,25 @@ class SSD1306(DisplayBase):
|
|||
cs_pin = config.get("cs_pin", None)
|
||||
if cs_pin is None:
|
||||
io = I2C(config, 60)
|
||||
io_bus = io.i2c
|
||||
else:
|
||||
io = SPI4wire(config, "dc_pin")
|
||||
io_bus = io.spi
|
||||
self.mcu_reset = None
|
||||
reset_pin_desc = config.get("reset_pin", None)
|
||||
if reset_pin_desc is not None:
|
||||
self.mcu_reset = extras.bus.MCU_bus_digital_out(
|
||||
io_bus.get_mcu(), reset_pin_desc, io_bus.get_command_queue())
|
||||
DisplayBase.__init__(self, io)
|
||||
def init(self):
|
||||
if self.mcu_reset is not None:
|
||||
mcu = self.mcu_reset.get_mcu()
|
||||
curtime = mcu.get_printer().get_reactor().monotonic()
|
||||
print_time = mcu.estimated_print_time(curtime)
|
||||
minclock = mcu.print_time_to_clock(print_time + .100)
|
||||
self.mcu_reset.update_digital_out(0, minclock=minclock)
|
||||
minclock = mcu.print_time_to_clock(print_time + .200)
|
||||
self.mcu_reset.update_digital_out(1, minclock=minclock)
|
||||
init_cmds = [
|
||||
0xAE, # Display off
|
||||
0xD5, 0x80, # Set oscillator frequency
|
||||
|
|