config: Move BME description within example-extras.cfg

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
Kevin O'Connor 2020-03-05 11:41:38 -05:00
parent f87e29c775
commit 8d10379ad8
1 changed files with 21 additions and 21 deletions

View File

@ -858,27 +858,6 @@
# chips. The defaults for each parameter are next to the parameter
# name in the above list.
# BME280 two wire interface (I2C) environmental sensor. Note that this
# sensor is not intended for use with extruders and heater beds, but rather
# for montitoring ambient temperature (C), pressure (hPa), and relative
# humidity. See sample-macros.cfg for a gcode_macro that may be used to report
# pressure and humidity in addition to temperature.
#[temperature_sensor my_sensor]
# See the "temperature_sensor" section below for a description of its
# parameters. The parameters below describe BME280 sensor parameters.
#sensor_type:
# Must be "BME280"
#i2c_address:
# Default is 118 (0x76). Some BME280 sensors have an address of 119 (0x77).
#i2c_mcu:
# MCU the sensor is connected to. Default is the primary mcu.
#i2c_bus:
# The I2C bus the sensor is connected to. On some MCU platforms the default
# is bus 0. On platforms without bus 0 this parameter is required.
#i2c_speed:
# The I2C speed (in Hz) to use when communicating with the sensor. Default
# is 100000. On some MCUs changing this value has no effect.
# Common temperature amplifiers. The following parameters are
# available in heater sections that use one of these sensors.
#[extruder]
@ -953,6 +932,27 @@
# pullup_resistor parameter (see example.cfg for details). At least
# two measurements must be provided.
# BME280 two wire interface (I2C) environmental sensor. Note that this
# sensor is not intended for use with extruders and heater beds, but rather
# for montitoring ambient temperature (C), pressure (hPa), and relative
# humidity. See sample-macros.cfg for a gcode_macro that may be used to report
# pressure and humidity in addition to temperature.
#[temperature_sensor my_sensor]
# See the "temperature_sensor" section below for a description of its
# parameters. The parameters below describe BME280 sensor parameters.
#sensor_type:
# Must be "BME280"
#i2c_address:
# Default is 118 (0x76). Some BME280 sensors have an address of 119 (0x77).
#i2c_mcu:
# MCU the sensor is connected to. Default is the primary mcu.
#i2c_bus:
# The I2C bus the sensor is connected to. On some MCU platforms the default
# is bus 0. On platforms without bus 0 this parameter is required.
#i2c_speed:
# The I2C speed (in Hz) to use when communicating with the sensor. Default
# is 100000. On some MCUs changing this value has no effect.
# Generic heaters (one may define any number of sections with a
# "heater_generic" prefix). These heaters behave similarly to standard
# heaters (extruders, heated beds). Use the SET_HEATER_TEMPERATURE