docs: Add FAQ item on AVR watchdog restart failures
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
319221ee23
commit
8944e2104d
15
docs/FAQ.md
15
docs/FAQ.md
|
@ -124,3 +124,18 @@ rates, but the stepper motor may not have sufficient torque to move at
|
|||
a higher speed. So, for a Z axis with a very precise step_distance the
|
||||
actual obtainable max_z_velocity may be smaller than what is
|
||||
configured in Marlin.
|
||||
|
||||
### When I set "restart_method=command" my AVR device just hangs on a restart
|
||||
|
||||
Some old versions of the AVR bootloader have a known bug in watchdog
|
||||
event handling. This typically manifests when the printer.cfg file has
|
||||
restart_method set to "command". When the bug occurs, the AVR device
|
||||
will be unresponsive until power is removed and reapplied to the
|
||||
device (the power or status LEDs may also blink repeatedly until the
|
||||
power is removed).
|
||||
|
||||
The workaround is to use a restart_method other than "command" or to
|
||||
flash an updated bootloader to the AVR devices. Flashing a new
|
||||
bootloader is a one time step that typically requires an external
|
||||
programmer - search the web to find the instructions for your
|
||||
particular device.
|
||||
|
|