Update printer-anycubic-vyper-2021.cfg (#5692)

* Update printer-anycubic-vyper-2021.cfg

better pause and end print, beeper support, mroe accurate value.

* Update printer-anycubic-vyper-2021.cfg

* Update printer-anycubic-vyper-2021.cfg

* Update printer-anycubic-vyper-2021.cfg

* Update printer-anycubic-vyper-2021.cfg

delete unnecessary gcode

* Update printer-anycubic-vyper-2021.cfg

remove unneccessary part.

* Update printer-anycubic-vyper-2021.cfg

* Update printer-anycubic-vyper-2021.cfg

according to https://www.klipper3d.org/Example_Configs.html point 7f
delete field values that are set to their default value

* Update printer-anycubic-vyper-2021.cfg

small change

* Update printer-anycubic-vyper-2021.cfg
This commit is contained in:
JackyHe398 2022-09-12 10:12:06 +08:00 committed by GitHub
parent a530bf2421
commit 721c764746
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
1 changed files with 14 additions and 2 deletions

View File

@ -70,7 +70,7 @@ step_pin: PB4
dir_pin: !PB3 dir_pin: !PB3
enable_pin: !PA15 enable_pin: !PA15
microsteps: 16 microsteps: 16
rotation_distance: 22.6789511 #has to be calibrated by everyone rotation_distance: 22.76500 #has to be calibrated by everyone, official document: diameter = 7.25
gear_ratio: 50:17 gear_ratio: 50:17
full_steps_per_rotation: 200 full_steps_per_rotation: 200
nozzle_diameter: 0.400 nozzle_diameter: 0.400
@ -108,13 +108,25 @@ z_offset: 0
activate_gcode: activate_gcode:
probe_reset probe_reset
[output_pin BEEPER_PIN]
pin: PB15
pwm: True
value: 0
shutdown_value: 0
cycle_time: 0.001
scale: 1
[output_pin probe_reset_pin] [output_pin probe_reset_pin]
pin: PB13 pin: PB13
[output_pin LED]
pin: mcu:PA13
pwm: False
value: 0
[bed_mesh] [bed_mesh]
mesh_min: 15,15 mesh_min: 15,15
mesh_max: 230, 230 mesh_max: 230, 230
probe_count: 6,6
[filament_switch_sensor runout] [filament_switch_sensor runout]