lcd_hd44780: Only calibrate cmd_wait_ticks on mcus with strict timing
The calibration isn't valid on the linux mcu, so make it dependent on CONFIG_HAVE_STRICT_TIMING. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
0cbb8fdc9a
commit
634dcc7387
|
@ -100,6 +100,11 @@ command_config_hd44780(uint32_t *args)
|
|||
h->d6 = gpio_out_setup(args[5], 0);
|
||||
h->d7 = gpio_out_setup(args[6], 0);
|
||||
|
||||
if (!CONFIG_HAVE_STRICT_TIMING) {
|
||||
h->cmd_wait_ticks = args[7];
|
||||
return;
|
||||
}
|
||||
|
||||
// Calibrate cmd_wait_ticks
|
||||
irq_disable();
|
||||
uint32_t start = timer_read_time();
|
||||
|
|