bme280: fix reported measured time
This allows the bme280 to correctly work with the temperature_fan module. Signed-off-by: Eric Callahan <arksine.code@gmail.com>
This commit is contained in:
parent
65ae08ef21
commit
4c571ea9ac
|
@ -27,6 +27,7 @@ class BME280:
|
|||
self.reactor = self.printer.get_reactor()
|
||||
self.i2c = bus.MCU_I2C_from_config(
|
||||
config, default_addr=BME280_CHIP_ADDR, default_speed=100000)
|
||||
self.mcu = self.i2c.get_mcu()
|
||||
self.os_temp = config.getint('bme280_oversample_temp', 2)
|
||||
self.os_hum = config.getint('bme280_oversample_hum', 2)
|
||||
self.os_pres = config.getint('bme280_oversample_pressure', 2)
|
||||
|
@ -132,7 +133,7 @@ class BME280:
|
|||
self.pressure = self._compensate_pressure(pressure_raw) / 100.
|
||||
self.humidity = self._compensate_humidity(humid_raw)
|
||||
measured_time = self.reactor.monotonic()
|
||||
self._callback(measured_time, self.temp)
|
||||
self._callback(self.mcu.estimated_print_time(measured_time), self.temp)
|
||||
return measured_time + REPORT_TIME
|
||||
|
||||
def _compensate_temp(self, raw_temp):
|
||||
|
|