# automatically enabled for each heater that is configured on the
# printer. Use verify_heater sections to change the default settings.
#[verify_heater heater_config_name]
#max_error: 120
# The maximum "cumulative temperature error" before raising an
# error. Smaller values result in stricter checking and larger
# values allow for more time before an error is reported.
# Specifically, the temperature is inspected once a second and if it
# is close to the target temperature then an internal "error
# counter" is reset; otherwise, if the temperature is below the
# target range then the counter is increased by the amount the
# reported temperature differs from that range. Should the counter
# exceed this "max_error" then an error is raised. The default is
# 120.
#check_gain_time:
# This controls heater verification during initial heating. Smaller
# values result in stricter checking and larger values allow for
# more time before an error is reported. Specifically, during
# initial heating, as long as the heater increases in temperature
# within this time frame (specified in seconds) then the internal
# "error counter" is reset. The default is 20 seconds for extruders
# and 60 seconds for heater_bed.
#hysteresis: 5
# The maximum temperature difference (in Celsius) to a target
# temperature that is considered in range of the target. This
# controls the max_error range check. It is rare to customize this
# value. The default is 5.
#heating_gain: 2
# The minimum temperature (in Celsius) that the heater must increase
# by when approaching a new target temperature. The default is 2.
#check_gain_time:
# The amount of time (in seconds) that the heating_gain must be met
# in before an error is raised. The default is 20 seconds for
# extruders and 60 seconds for heater_bed.
#hysteresis: 5
# The difference between the target temperature and the current
# temperature for the heater to be considered within range of the
# target temperature. The default is 5.
#max_error: 120
# The maximum temperature difference a heater that falls outside the
# target temperature range may accumulate before an error is
# raised. For example, if the target temperature is 200, the
# hysteresis is 5, the max_error is 120, and the temperature is
# reported at 185 degrees for 12 seconds then an error would be
# raised (or 24 seconds at 190, or 120 seconds at 194, etc.). The
# default is 120.
# by during the check_gain_time check. It is rare to customize this
# value. The default is 2.
# Idle timeout. An idle timeout is automatically enabled - add an