config: Update verify_heater description
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
8f37700d23
commit
47d51d8613
|
@ -389,25 +389,34 @@
|
|||
# automatically enabled for each heater that is configured on the
|
||||
# printer. Use verify_heater sections to change the default settings.
|
||||
#[verify_heater heater_config_name]
|
||||
#max_error: 120
|
||||
# The maximum "cumulative temperature error" before raising an
|
||||
# error. Smaller values result in stricter checking and larger
|
||||
# values allow for more time before an error is reported.
|
||||
# Specifically, the temperature is inspected once a second and if it
|
||||
# is close to the target temperature then an internal "error
|
||||
# counter" is reset; otherwise, if the temperature is below the
|
||||
# target range then the counter is increased by the amount the
|
||||
# reported temperature differs from that range. Should the counter
|
||||
# exceed this "max_error" then an error is raised. The default is
|
||||
# 120.
|
||||
#check_gain_time:
|
||||
# This controls heater verification during initial heating. Smaller
|
||||
# values result in stricter checking and larger values allow for
|
||||
# more time before an error is reported. Specifically, during
|
||||
# initial heating, as long as the heater increases in temperature
|
||||
# within this time frame (specified in seconds) then the internal
|
||||
# "error counter" is reset. The default is 20 seconds for extruders
|
||||
# and 60 seconds for heater_bed.
|
||||
#hysteresis: 5
|
||||
# The maximum temperature difference (in Celsius) to a target
|
||||
# temperature that is considered in range of the target. This
|
||||
# controls the max_error range check. It is rare to customize this
|
||||
# value. The default is 5.
|
||||
#heating_gain: 2
|
||||
# The minimum temperature (in Celsius) that the heater must increase
|
||||
# by when approaching a new target temperature. The default is 2.
|
||||
#check_gain_time:
|
||||
# The amount of time (in seconds) that the heating_gain must be met
|
||||
# in before an error is raised. The default is 20 seconds for
|
||||
# extruders and 60 seconds for heater_bed.
|
||||
#hysteresis: 5
|
||||
# The difference between the target temperature and the current
|
||||
# temperature for the heater to be considered within range of the
|
||||
# target temperature. The default is 5.
|
||||
#max_error: 120
|
||||
# The maximum temperature difference a heater that falls outside the
|
||||
# target temperature range may accumulate before an error is
|
||||
# raised. For example, if the target temperature is 200, the
|
||||
# hysteresis is 5, the max_error is 120, and the temperature is
|
||||
# reported at 185 degrees for 12 seconds then an error would be
|
||||
# raised (or 24 seconds at 190, or 120 seconds at 194, etc.). The
|
||||
# default is 120.
|
||||
# by during the check_gain_time check. It is rare to customize this
|
||||
# value. The default is 2.
|
||||
|
||||
|
||||
# Idle timeout. An idle timeout is automatically enabled - add an
|
||||
|
|