Followed general outline used by HTU21D and BME280. Signed-off-by: Scott Mudge <mail@scottmudge.com>
This commit is contained in:
parent
a8b1b0ef05
commit
4748dffd7a
|
@ -2375,6 +2375,29 @@ sensor_type: BME280
|
||||||
# above parameters.
|
# above parameters.
|
||||||
```
|
```
|
||||||
|
|
||||||
|
### AHT10 temperature sensor
|
||||||
|
|
||||||
|
AHT10 two wire interface (I2C) environmental sensor.
|
||||||
|
Note that these sensors are not intended for use with extruders and
|
||||||
|
heater beds, but rather for monitoring ambient temperature (C) and
|
||||||
|
relative humidity. See
|
||||||
|
[sample-macros.cfg](../config/sample-macros.cfg) for a gcode_macro
|
||||||
|
that may be used to report humidity in addition to temperature.
|
||||||
|
|
||||||
|
```
|
||||||
|
sensor_type: AHT10
|
||||||
|
#i2c_address:
|
||||||
|
# Default is 56 (0x38). Some AHT10 sensors give the option to use
|
||||||
|
# 57 (0x39) by moving a resistor.
|
||||||
|
#i2c_mcu:
|
||||||
|
#i2c_bus:
|
||||||
|
#i2c_speed:
|
||||||
|
# See the "common I2C settings" section for a description of the
|
||||||
|
# above parameters.
|
||||||
|
#aht10_report_time:
|
||||||
|
# Interval in seconds between readings. Default is 30, minimum is 5
|
||||||
|
```
|
||||||
|
|
||||||
### HTU21D sensor
|
### HTU21D sensor
|
||||||
|
|
||||||
HTU21D family two wire interface (I2C) environmental sensor. Note that
|
HTU21D family two wire interface (I2C) environmental sensor. Note that
|
||||||
|
|
Loading…
Reference in New Issue