klippy: Replace deprecated logger.warn with logger.warning (#6385)

Replace deprecated logger.warn with logger.warning

logger.warn will be removed in Python 3.13

Signed-off-by: Thijs Triemstra <info@collab.nl>
This commit is contained in:
Thijs Triemstra 2023-11-17 04:06:13 +01:00 committed by GitHub
parent 3f8f30d612
commit 4688c21c54
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
6 changed files with 19 additions and 16 deletions

View File

@ -172,16 +172,16 @@ class PrinterConfig:
autosave_data = data[pos + len(AUTOSAVE_HEADER):].strip() autosave_data = data[pos + len(AUTOSAVE_HEADER):].strip()
# Check for errors and strip line prefixes # Check for errors and strip line prefixes
if "\n#*# " in regular_data: if "\n#*# " in regular_data:
logging.warn("Can't read autosave from config file" logging.warning("Can't read autosave from config file"
" - autosave state corrupted") " - autosave state corrupted")
return data, "" return data, ""
out = [""] out = [""]
for line in autosave_data.split('\n'): for line in autosave_data.split('\n'):
if ((not line.startswith("#*#") if ((not line.startswith("#*#")
or (len(line) >= 4 and not line.startswith("#*# "))) or (len(line) >= 4 and not line.startswith("#*# ")))
and autosave_data): and autosave_data):
logging.warn("Can't read autosave from config file" logging.warning("Can't read autosave from config file"
" - modifications after header") " - modifications after header")
return data, "" return data, ""
out.append(line[4:]) out.append(line[4:])
out.append("") out.append("")

View File

@ -95,8 +95,8 @@ class LinearVoltage:
for temp, volt in params: for temp, volt in params:
adc = (volt - voltage_offset) / adc_voltage adc = (volt - voltage_offset) / adc_voltage
if adc < 0. or adc > 1.: if adc < 0. or adc > 1.:
logging.warn("Ignoring adc sample %.3f/%.3f in heater %s", logging.warning("Ignoring adc sample %.3f/%.3f in heater %s",
temp, volt, config.get_name()) temp, volt, config.get_name())
continue continue
samples.append((adc, temp)) samples.append((adc, temp))
try: try:

View File

@ -126,7 +126,7 @@ class HTU21D:
rdevId |= response[1] rdevId |= response[1]
checksum = response[2] checksum = response[2]
if self._chekCRC8(rdevId) != checksum: if self._chekCRC8(rdevId) != checksum:
logging.warn("htu21d: Reading deviceId !Checksum error!") logging.warning("htu21d: Reading deviceId !Checksum error!")
rdevId = rdevId >> 8 rdevId = rdevId >> 8
deviceId_list = list( deviceId_list = list(
filter( filter(
@ -135,10 +135,10 @@ class HTU21D:
if len(deviceId_list) != 0: if len(deviceId_list) != 0:
logging.info("htu21d: Found Device Type %s" % deviceId_list[0]) logging.info("htu21d: Found Device Type %s" % deviceId_list[0])
else: else:
logging.warn("htu21d: Unknown Device ID %#x " % rdevId) logging.warning("htu21d: Unknown Device ID %#x " % rdevId)
if(self.deviceId != deviceId_list[0]): if self.deviceId != deviceId_list[0]:
logging.warn( logging.warning(
"htu21d: Found device %s. Forcing to type %s as config.", "htu21d: Found device %s. Forcing to type %s as config.",
deviceId_list[0],self.deviceId) deviceId_list[0],self.deviceId)
@ -169,7 +169,9 @@ class HTU21D:
rtemp = response[0] << 8 rtemp = response[0] << 8
rtemp |= response[1] rtemp |= response[1]
if self._chekCRC8(rtemp) != response[2]: if self._chekCRC8(rtemp) != response[2]:
logging.warn("htu21d: Checksum error on Temperature reading!") logging.warning(
"htu21d: Checksum error on Temperature reading!"
)
else: else:
self.temp = (0.002681 * float(rtemp) - 46.85) self.temp = (0.002681 * float(rtemp) - 46.85)
logging.debug("htu21d: Temperature %.2f " % self.temp) logging.debug("htu21d: Temperature %.2f " % self.temp)
@ -190,7 +192,7 @@ class HTU21D:
rhumid = response[0] << 8 rhumid = response[0] << 8
rhumid|= response[1] rhumid|= response[1]
if self._chekCRC8(rhumid) != response[2]: if self._chekCRC8(rhumid) != response[2]:
logging.warn("htu21d: Checksum error on Humidity reading!") logging.warning("htu21d: Checksum error on Humidity reading!")
else: else:
#clear status bits, #clear status bits,
# humidity always returns xxxxxx10 in the LSB field # humidity always returns xxxxxx10 in the LSB field

View File

@ -62,7 +62,7 @@ class SensorBase:
last_read_time = self.mcu.clock_to_print_time(last_read_clock) last_read_time = self.mcu.clock_to_print_time(last_read_clock)
self._callback(last_read_time, temp) self._callback(last_read_time, temp)
def report_fault(self, msg): def report_fault(self, msg):
logging.warn(msg) logging.warning(msg)
###################################################################### ######################################################################

View File

@ -33,7 +33,8 @@ class Thermistor:
/ (ln3_r12 - ln3_r13 * ln_r12 / ln_r13)) / (ln3_r12 - ln3_r13 * ln_r12 / ln_r13))
if self.c3 <= 0.: if self.c3 <= 0.:
beta = ln_r13 / inv_t13 beta = ln_r13 / inv_t13
logging.warn("Using thermistor beta %.3f in heater %s", beta, name) logging.warning("Using thermistor beta %.3f in heater %s",
beta, name)
self.setup_coefficients_beta(t1, r1, beta) self.setup_coefficients_beta(t1, r1, beta)
return return
self.c2 = (inv_t12 - self.c3 * ln3_r12) / ln_r12 self.c2 = (inv_t12 - self.c3 * ln3_r12) / ln_r12

View File

@ -137,8 +137,8 @@ class SerialReader:
bustype='socketcan') bustype='socketcan')
bus.send(set_id_msg) bus.send(set_id_msg)
except (can.CanError, os.error) as e: except (can.CanError, os.error) as e:
logging.warn("%sUnable to open CAN port: %s", logging.warning("%sUnable to open CAN port: %s",
self.warn_prefix, e) self.warn_prefix, e)
self.reactor.pause(self.reactor.monotonic() + 5.) self.reactor.pause(self.reactor.monotonic() + 5.)
continue continue
bus.close = bus.shutdown # XXX bus.close = bus.shutdown # XXX