From 439f6684bee4f4cd884e24cd6f5409632c9ab2f9 Mon Sep 17 00:00:00 2001 From: Kevin O'Connor Date: Wed, 26 Sep 2018 08:16:40 -0400 Subject: [PATCH] config: Move some sections around in example-extras.cfg Move the quad_gantry_level description closer to z_tilt section. Move the force_move section closer to the homing_override section. Signed-off-by: Kevin O'Connor --- config/example-extras.cfg | 102 ++++++++++++++++++++------------------ 1 file changed, 53 insertions(+), 49 deletions(-) diff --git a/config/example-extras.cfg b/config/example-extras.cfg index 1ec4a1cb..9eed2993 100644 --- a/config/example-extras.cfg +++ b/config/example-extras.cfg @@ -174,6 +174,48 @@ # The distance (in mm) to retract between each sample if # sampling more than once. Default is 2mm. + +# Moving gantry leveling using 4 independently controlled Z motors. +# Corrects hyperbolic parabola effects (potato chip) on moving gantry +# which is more flexible. +# WARNING: Using this on a moving bed may lead to undesirable results. +# If this section is present then a QUAD_GANTRY_LEVEL extended G-Code +# command becomes available. This routine assumes the following Z motor +# configuration: +# ---------------- +# |Z1 Z2| +# | --------- | +# | | | | +# | | | | +# | x-------- | +# |Z Z3| +# ---------------- +# Where x is the (0,0) point on the bed +#[quad_gantry_level] +#gantry_corners: +# A newline separated list of X,Y coordinates describing the +# two opposing corners of the gantry. The first entry corresponds to +# Z, the second to Z2. +# This parameter must be provided. +#points: +# A newline separated list of four X,Y points that should be probed +# during a QUAD_GANTRY_LEVEL command. +# Order of the locations is important, and should correspond to Z,Z1 +# Z2, and Z3 location in order. +# This parameter must be provided. +# For maximum accuracy, ensure your probe offsets are configured. +#speed: 50 +# The speed (in mm/s) of non-probing moves during the calibration. +# The default is 50. +#horizontal_move_z: 5 +# The height (in mm) that the head should be commanded to move to +# just prior to starting a probe operation. The default is 5 +#samples: 1 +# Number of probe samples per point. The defaut is 1 +#sample_retract_dist: 2.0 +# Distance in mm to retract the probe between samples. Default is 2. + + # In a multi-extruder printer add an additional extruder section for # each additional extruder. The additional extruder sections should be # named "extruder1", "extruder2", "extruder3", and so on. See the @@ -608,6 +650,7 @@ # to an appropriate sensitivity value.) The default is to not enable # sensorless homing. + # Configure a TMC2208 (or TMC2224) stepper motor driver via single # wire UART. To use this feature, define a config section with a # "tmc2208" prefix followed by the name of the corresponding stepper @@ -770,6 +813,15 @@ # axis. The default is to not force a position for an axis. +# Support manually moving stepper motors for diagnostic purposes. +# Note, using this feature may place the printer in an invalid state - +# see docs/G-Codes.md for important details. +#[force_move] +#enable_force_move: False +# Set to true to enable FORCE_MOVE and SET_KINEMATIC_POSITION +# extended G-Code commands. The default is false. + + # A virtual sdcard may be useful if the host machine is not fast # enough to run OctoPrint well. It allows the Klipper host software to # directly print gcode files stored in a directory on the host using @@ -836,6 +888,7 @@ # The pin connected to 'kill' button. This button will call # emergency stop. + # Custom thermistors (one may define any number of sections with a # "thermistor" prefix). A custom thermistor may be used in the # sensor_type field of a heater config section. (For example, if one @@ -912,15 +965,6 @@ # name in the above list. -# Support manually moving stepper motors for diagnostic purposes. -# Note, using this feature may place the printer in an invalid state - -# see docs/G-Codes.md for important details. -#[force_move] -#enable_force_move: False -# Set to true to enable FORCE_MOVE and SET_KINEMATIC_POSITION -# extended G-Code commands. The default is false. - - # G-Code macros (one may define any number of sections with a # "gcode_macro" prefix). #[gcode_macro my_cmd] @@ -933,43 +977,3 @@ # Replicape support - see the generic-replicape.cfg file for further # details. #[replicape] - -# Moving gantry leveling using 4 independently controlled Z motors. -# Corrects hyperbolic parabola effects (potato chip) on moving gantry -# which is more flexible. -# WARNING: Using this on a moving bed may lead to undesirable results. -# If this section is present then a QUAD_GANTRY_LEVEL extended G-Code -# command becomes available. This routine assumes the following Z motor -# configuration: -# ---------------- -# |Z1 Z2| -# | --------- | -# | | | | -# | | | | -# | x-------- | -# |Z Z3| -# ---------------- -# Where x is the (0,0) point on the bed -#[quad_gantry_level] -#gantry_corners: -# A newline separated list of X,Y coordinates describing the -# two opposing corners of the gantry. The first entry corresponds to -# Z, the second to Z2. -# This parameter must be provided. -#points: -# A newline separated list of four X,Y points that should be probed -# during a QUAD_GANTRY_LEVEL command. -# Order of the locations is important, and should correspond to Z,Z1 -# Z2, and Z3 location in order. -# This parameter must be provided. -# For maximum accuracy, ensure your probe offsets are configured. -#speed: 50 -# The speed (in mm/s) of non-probing moves during the calibration. -# The default is 50. -#horizontal_move_z: 5 -# The height (in mm) that the head should be commanded to move to -# just prior to starting a probe operation. The default is 5 -#samples: 1 -# Number of probe samples per point. The defaut is 1 -#sample_retract_dist: 2.0 -# Distance in mm to retract the probe between samples. Default is 2.