### Calibration
|
### Calibration
|
||||||
|
|
||||||
`BED_MESH_CALIBRATE METHOD=[manual | automatic]`\
|
`BED_MESH_CALIBRATE METHOD=[manual | automatic] [<probe_parameter>=<value>]
|
||||||
|
[<mesh_parameter>=<value>]`\
|
||||||
_Default Method: automatic if a probe is detected, otherwise manual_
|
_Default Method: automatic if a probe is detected, otherwise manual_
|
||||||
|
|
||||||
Initiates the probing procedure for Bed Mesh Calibration. If `METHOD=manual`
|
Initiates the probing procedure for Bed Mesh Calibration. If `METHOD=manual`
|
||||||
is selected then manual probing will occur. When switching between automatic
|
is selected then manual probing will occur. When switching between automatic
|
||||||
and manual probing the generated mesh points will automatically be adjusted.
|
and manual probing the generated mesh points will automatically be adjusted.
|
||||||
|
|
||||||
|
It is possible to specify mesh parameters to modify the probed area. The
|
||||||
|
following parameters are available:
|
||||||
|
- Rectangular beds (cartesian):
|
||||||
|
- `MESH_MIN`
|
||||||
|
- `MESH_MAX`
|
||||||
|
- `PROBE_COUNT`
|
||||||
|
- Round beds (delta):
|
||||||
|
- `MESH_RADIUS`
|
||||||
|
- `MESH_ORIGIN`
|
||||||
|
- `ROUND_PROBE_COUNT`
|
||||||
|
- All beds:
|
||||||
|
- `RELATIVE_REFERNCE_INDEX`
|
||||||
|
- `ALGORITHM`
|
||||||
|
See the configuration documentation above for details on how each parameter
|
||||||
|
applies to the mesh.
|
||||||
|
|
||||||
### Profiles
|
### Profiles
|
||||||
|
|
||||||
`BED_MESH_PROFILE SAVE=name LOAD=name REMOVE=name`
|
`BED_MESH_PROFILE SAVE=name LOAD=name REMOVE=name`
|
||||||
|
@ -357,3 +374,9 @@ set, the generated probed points will be output to the terminal:
|
||||||
The "Tool Adjusted" points refer to the nozzle location for each point, and
|
The "Tool Adjusted" points refer to the nozzle location for each point, and
|
||||||
the "Probe" points refer to the probe location. Note that when manually
|
the "Probe" points refer to the probe location. Note that when manually
|
||||||
probing the "Probe" points will refer to both the tool and nozzle locations.
|
probing the "Probe" points will refer to both the tool and nozzle locations.
|
||||||
|
|
||||||
|
### Clear Mesh State
|
||||||
|
|
||||||
|
`BED_MESH_CLEAR`
|
||||||
|
|
||||||
|
This gcode may be used to clear the internal mesh state.
|
||||||
|
|
|
@ -382,7 +382,8 @@ section is enabled:
|
||||||
|
|
||||||
The following commands are available when the "bed_mesh" config
|
The following commands are available when the "bed_mesh" config
|
||||||
section is enabled:
|
section is enabled:
|
||||||
- `BED_MESH_CALIBRATE [METHOD=manual] [<probe_parameter>=<value>]`:
|
- `BED_MESH_CALIBRATE [METHOD=manual] [<probe_parameter>=<value>]
|
||||||
|
[<mesh_parameter>=<value>]`:
|
||||||
This command probes the bed using generated points specified by the
|
This command probes the bed using generated points specified by the
|
||||||
parameters in the config. After probing, a mesh is generated and
|
parameters in the config. After probing, a mesh is generated and
|
||||||
z-movement is adjusted according to the mesh. See the PROBE command
|
z-movement is adjusted according to the mesh. See the PROBE command
|
||||||
|
|