docs: Recommend normal slicer settings in Pressure_Advance.md
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
3683273936
commit
3aad25eab9
|
@ -97,6 +97,15 @@ Important Notes
|
||||||
[nozzle temperature](http://reprap.org/wiki/Triffid_Hunter%27s_Calibration_Guide#Nozzle_Temperature)
|
[nozzle temperature](http://reprap.org/wiki/Triffid_Hunter%27s_Calibration_Guide#Nozzle_Temperature)
|
||||||
prior to tuning pressure advance.
|
prior to tuning pressure advance.
|
||||||
|
|
||||||
|
* The test print is designed to run with a high extruder flow rate,
|
||||||
|
but otherwise "normal" slicer settings. A high flow rate is obtained
|
||||||
|
by using a high printing speed (eg, 100mm/s) and a coarse layer
|
||||||
|
height (typically around 75% of the nozzle diameter). Other slicer
|
||||||
|
settings should be similar to their defaults (eg, perimeters of 2 or
|
||||||
|
3 layers, normal retraction amount). It can be useful to set the
|
||||||
|
external perimeter speed to be the same speed as the rest of the
|
||||||
|
print, but it is not a requirement.
|
||||||
|
|
||||||
* It is common for the test print to show different behavior on each
|
* It is common for the test print to show different behavior on each
|
||||||
corner. Often the slicer will arrange to change layers at one corner
|
corner. Often the slicer will arrange to change layers at one corner
|
||||||
which can result in that corner being significantly different from
|
which can result in that corner being significantly different from
|
||||||
|
|