config: Note adc_voltage and pullup_resistance in adc_temperature module
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
49779f13a2
commit
361de30ad1
|
@ -1527,8 +1527,10 @@
|
||||||
#voltage2:
|
#voltage2:
|
||||||
#...
|
#...
|
||||||
# A set of temperatures (in Celsius) and voltages (in Volts) to use
|
# A set of temperatures (in Celsius) and voltages (in Volts) to use
|
||||||
# as reference when converting a temperature. At least two
|
# as reference when converting a temperature. A heater section using
|
||||||
# measurements must be provided.
|
# this sensor may also specify an adc_voltage parameter to define
|
||||||
|
# the ADC comparison voltage (see example.cfg for details). At least
|
||||||
|
# two measurements must be provided.
|
||||||
#temperature1:
|
#temperature1:
|
||||||
#resistance1:
|
#resistance1:
|
||||||
#temperature2:
|
#temperature2:
|
||||||
|
@ -1536,7 +1538,9 @@
|
||||||
#...
|
#...
|
||||||
# Alternatively one may specify a set of temperatures (in Celsius)
|
# Alternatively one may specify a set of temperatures (in Celsius)
|
||||||
# and resistance (in Ohms) to use as reference when converting a
|
# and resistance (in Ohms) to use as reference when converting a
|
||||||
# temperature. At least two measurements must be provided.
|
# temperature. A heater section using this sensor may also specify a
|
||||||
|
# pullup_resistor parameter (see example.cfg for details). At least
|
||||||
|
# two measurements must be provided.
|
||||||
|
|
||||||
|
|
||||||
# MAXxxxxx serial peripheral interface (SPI) temperature based
|
# MAXxxxxx serial peripheral interface (SPI) temperature based
|
||||||
|
|
Loading…
Reference in New Issue