config: The delta_calibrate bed radius uses nozzle coordinates
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
43f2eac239
commit
31ec098577
|
@ -113,17 +113,19 @@ delta_radius: 174.75
|
||||||
# angles.
|
# angles.
|
||||||
[delta_calibrate]
|
[delta_calibrate]
|
||||||
radius: 50
|
radius: 50
|
||||||
# Radius (in mm) of the area that may be probed. This is typically
|
# Radius (in mm) of the area that may be probed. This is the radius
|
||||||
# the size of the printer bed. This parameter must be provided.
|
# of nozzle coordinates to be probed; if using an automatic probe
|
||||||
|
# with an XY offset then choose a radius small enough so that the
|
||||||
|
# probe always fits over the bed. This parameter must be provided.
|
||||||
#speed: 50
|
#speed: 50
|
||||||
# The speed (in mm/s) of non-probing moves during the
|
# The speed (in mm/s) of non-probing moves during the calibration.
|
||||||
# calibration. The default is 50.
|
# The default is 50.
|
||||||
#horizontal_move_z: 5
|
#horizontal_move_z: 5
|
||||||
# The height (in mm) that the head should be commanded to move to
|
# The height (in mm) that the head should be commanded to move to
|
||||||
# just prior to starting a probe operation. The default is 5.
|
# just prior to starting a probe operation. The default is 5.
|
||||||
#samples: 1
|
#samples: 1
|
||||||
# The number of times to probe each point. The probed z-values
|
# The number of times to probe each point. The probed z-values will
|
||||||
# will be averaged. The default is to probe 1 time.
|
# be averaged. The default is to probe 1 time.
|
||||||
#sample_retract_dist: 2.0
|
#sample_retract_dist: 2.0
|
||||||
# The distance (in mm) to retract between each sample if
|
# The distance (in mm) to retract between each sample if sampling
|
||||||
# sampling more than once. Default is 2mm.
|
# more than once. The default is 2mm.
|
||||||
|
|
Loading…
Reference in New Issue