config: The delta_calibrate bed radius uses nozzle coordinates

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
Kevin O'Connor 2018-09-26 14:39:06 -04:00 committed by KevinOConnor
parent 43f2eac239
commit 31ec098577
1 changed files with 10 additions and 8 deletions

View File

@ -113,17 +113,19 @@ delta_radius: 174.75
# angles. # angles.
[delta_calibrate] [delta_calibrate]
radius: 50 radius: 50
# Radius (in mm) of the area that may be probed. This is typically # Radius (in mm) of the area that may be probed. This is the radius
# the size of the printer bed. This parameter must be provided. # of nozzle coordinates to be probed; if using an automatic probe
# with an XY offset then choose a radius small enough so that the
# probe always fits over the bed. This parameter must be provided.
#speed: 50 #speed: 50
# The speed (in mm/s) of non-probing moves during the # The speed (in mm/s) of non-probing moves during the calibration.
# calibration. The default is 50. # The default is 50.
#horizontal_move_z: 5 #horizontal_move_z: 5
# The height (in mm) that the head should be commanded to move to # The height (in mm) that the head should be commanded to move to
# just prior to starting a probe operation. The default is 5. # just prior to starting a probe operation. The default is 5.
#samples: 1 #samples: 1
# The number of times to probe each point. The probed z-values # The number of times to probe each point. The probed z-values will
# will be averaged. The default is to probe 1 time. # be averaged. The default is to probe 1 time.
#sample_retract_dist: 2.0 #sample_retract_dist: 2.0
# The distance (in mm) to retract between each sample if # The distance (in mm) to retract between each sample if sampling
# sampling more than once. Default is 2mm. # more than once. The default is 2mm.