spi_temperature: Remove non-spi flags from SensorBase
The SensorBase class is used exclusively for SPI transfers, so no need to track non-spi settings. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
c0bf4327fd
commit
270080cd4c
|
@ -10,9 +10,7 @@ import math
|
|||
# SensorBase
|
||||
######################################################################
|
||||
|
||||
SAMPLE_TIME_DEFAULT = 0.001
|
||||
SAMPLE_COUNT_DEFAULT = 8
|
||||
REPORT_TIME_DEFAULT = 0.300
|
||||
REPORT_TIME = 0.300
|
||||
|
||||
VALID_SPI_SENSORS = {
|
||||
'MAX31855' : 1,
|
||||
|
@ -24,18 +22,9 @@ VALID_SPI_SENSORS = {
|
|||
class error(Exception):
|
||||
pass
|
||||
|
||||
class SensorBase(object):
|
||||
class SensorBase:
|
||||
error = error
|
||||
def __init__(self,
|
||||
config,
|
||||
is_spi = False,
|
||||
sample_time = SAMPLE_TIME_DEFAULT,
|
||||
sample_count = SAMPLE_COUNT_DEFAULT,
|
||||
report_time = REPORT_TIME_DEFAULT):
|
||||
self.is_spi = is_spi
|
||||
self.sample_time = sample_time
|
||||
self.sample_count = sample_count
|
||||
self.report_time = report_time
|
||||
def __init__(self, config):
|
||||
self.min_temp = config.getfloat('min_temp', minval=0., default=0.)
|
||||
self.max_temp = config.getfloat('max_temp', above=self.min_temp)
|
||||
self._callback = None
|
||||
|
@ -46,7 +35,6 @@ class SensorBase(object):
|
|||
self.max_sample_value = max(adc_range)
|
||||
self._report_clock = 0
|
||||
ppins = config.get_printer().lookup_object('pins')
|
||||
if is_spi:
|
||||
pin_params = ppins.lookup_pin('digital_out', sensor_pin)
|
||||
self.mcu = mcu = pin_params['chip']
|
||||
pin = pin_params['pin']
|
||||
|
@ -69,23 +57,15 @@ class SensorBase(object):
|
|||
mcu.register_msg(self._handle_spi_response,
|
||||
"thermocouple_result", oid)
|
||||
mcu.add_config_object(self)
|
||||
else:
|
||||
self.mcu = ppins.setup_pin('adc', sensor_pin)
|
||||
self.mcu.setup_minmax(
|
||||
sample_time, sample_count,
|
||||
minval=min(adc_range), maxval=max(adc_range))
|
||||
def setup_minmax(self, min_temp, max_temp):
|
||||
pass
|
||||
def setup_callback(self, cb):
|
||||
if self.is_spi:
|
||||
self._callback = cb
|
||||
else:
|
||||
self.mcu.setup_callback(self.report_time, cb)
|
||||
def get_report_time_delta(self):
|
||||
return self.report_time
|
||||
return REPORT_TIME
|
||||
def build_config(self):
|
||||
clock = self.mcu.get_query_slot(self.oid)
|
||||
self._report_clock = self.mcu.seconds_to_clock(self.report_time)
|
||||
self._report_clock = self.mcu.seconds_to_clock(REPORT_TIME)
|
||||
self.mcu.add_config_cmd(
|
||||
"query_thermocouple oid=%u clock=%u rest_ticks=%u"
|
||||
" min_value=%u max_value=%u" % (
|
||||
|
@ -187,7 +167,7 @@ class Thermocouple(SensorBase):
|
|||
else:
|
||||
self.val_a = 0.25
|
||||
self.scale = 18
|
||||
SensorBase.__init__(self, config, is_spi = True, sample_count = 1)
|
||||
SensorBase.__init__(self, config)
|
||||
def _check_faults_simple(self, val):
|
||||
if self.chip_type == "MAX6675":
|
||||
if val & 0x02:
|
||||
|
@ -295,7 +275,7 @@ class RTD(SensorBase):
|
|||
self.reference_r = config.getfloat('rtd_reference_r', 430., above=0.)
|
||||
self.num_wires = config.getint('rtd_num_of_wires', 2)
|
||||
self.use_50Hz_filter = config.getboolean('rtd_use_50Hz_filter', False)
|
||||
SensorBase.__init__(self, config, is_spi = True, sample_count = 1)
|
||||
SensorBase.__init__(self, config)
|
||||
def check_faults(self, fault):
|
||||
if fault & 0x80:
|
||||
raise self.error("Max31865 RTD input is disconnected")
|
||||
|
|
Loading…
Reference in New Issue