mcu: Reset pwm and digital output pins to start values on a host restart
This makes sure output pins are reset to their defaults when the host is restarted and the micro-controller is not. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
d204cc1fb7
commit
122fd88c6a
|
@ -140,8 +140,8 @@ class MCU_digital_out:
|
|||
self._is_static = is_static
|
||||
def _build_config(self):
|
||||
if self._is_static:
|
||||
self._mcu.add_config_cmd("set_digital_out pin=%s value=%d" % (
|
||||
self._pin, self._start_value))
|
||||
self._mcu.add_config_cmd("set_digital_out pin=%s value=%d"
|
||||
% (self._pin, self._start_value))
|
||||
return
|
||||
self._oid = self._mcu.create_oid()
|
||||
self._mcu.add_config_cmd(
|
||||
|
@ -149,6 +149,9 @@ class MCU_digital_out:
|
|||
" max_duration=%d" % (
|
||||
self._oid, self._pin, self._start_value, self._shutdown_value,
|
||||
self._mcu.seconds_to_clock(self._max_duration)))
|
||||
self._mcu.add_config_cmd("update_digital_out oid=%d value=%d"
|
||||
% (self._oid, self._start_value),
|
||||
on_restart=True)
|
||||
cmd_queue = self._mcu.alloc_command_queue()
|
||||
self._set_cmd = self._mcu.lookup_command(
|
||||
"schedule_digital_out oid=%c clock=%u value=%c", cq=cmd_queue)
|
||||
|
@ -198,45 +201,50 @@ class MCU_pwm:
|
|||
self._pwm_max = self._mcu.get_constant_float("PWM_MAX")
|
||||
if self._is_static:
|
||||
self._mcu.add_config_cmd(
|
||||
"set_pwm_out pin=%s cycle_ticks=%d value=%d" % (
|
||||
self._pin, cycle_ticks,
|
||||
self._start_value * self._pwm_max))
|
||||
"set_pwm_out pin=%s cycle_ticks=%d value=%d"
|
||||
% (self._pin, cycle_ticks,
|
||||
self._start_value * self._pwm_max))
|
||||
return
|
||||
self._oid = self._mcu.create_oid()
|
||||
self._mcu.add_config_cmd(
|
||||
"config_pwm_out oid=%d pin=%s cycle_ticks=%d value=%d"
|
||||
" default_value=%d max_duration=%d" % (
|
||||
self._oid, self._pin, cycle_ticks,
|
||||
self._start_value * self._pwm_max,
|
||||
self._shutdown_value * self._pwm_max,
|
||||
self._mcu.seconds_to_clock(self._max_duration)))
|
||||
" default_value=%d max_duration=%d"
|
||||
% (self._oid, self._pin, cycle_ticks,
|
||||
self._start_value * self._pwm_max,
|
||||
self._shutdown_value * self._pwm_max,
|
||||
self._mcu.seconds_to_clock(self._max_duration)))
|
||||
self._mcu.add_config_cmd(
|
||||
"set_pwm_out pin=%s cycle_ticks=%d value=%d"
|
||||
% (self._pin, cycle_ticks, self._start_value * self._pwm_max),
|
||||
on_restart=True)
|
||||
self._set_cmd = self._mcu.lookup_command(
|
||||
"schedule_pwm_out oid=%c clock=%u value=%hu", cq=cmd_queue)
|
||||
else:
|
||||
if self._shutdown_value not in [0., 1.]:
|
||||
raise pins.error(
|
||||
"shutdown value must be 0.0 or 1.0 on soft pwm")
|
||||
self._pwm_max = float(cycle_ticks)
|
||||
if self._is_static:
|
||||
self._mcu.add_config_cmd("set_digital_out pin=%s value=%d" % (
|
||||
self._pin, self._start_value >= 0.5))
|
||||
return
|
||||
self._oid = self._mcu.create_oid()
|
||||
self._mcu.add_config_cmd(
|
||||
"config_soft_pwm_out oid=%d pin=%s cycle_ticks=%d value=%d"
|
||||
" default_value=%d max_duration=%d" % (
|
||||
self._oid, self._pin, cycle_ticks,
|
||||
self._start_value >= 1.0, self._shutdown_value >= 0.5,
|
||||
self._mcu.seconds_to_clock(self._max_duration)))
|
||||
if self._start_value not in [0., 1.]:
|
||||
clock = self._mcu.get_query_slot(self._oid)
|
||||
svalue = int(self._start_value * self._pwm_max + 0.5)
|
||||
self._mcu.add_config_cmd(
|
||||
"schedule_soft_pwm_out oid=%d clock=%d on_ticks=%d" % (
|
||||
self._oid, clock, svalue))
|
||||
self._set_cmd = self._mcu.lookup_command(
|
||||
"schedule_soft_pwm_out oid=%c clock=%u on_ticks=%u",
|
||||
cq=cmd_queue)
|
||||
return
|
||||
# Software PWM
|
||||
if self._shutdown_value not in [0., 1.]:
|
||||
raise pins.error("shutdown value must be 0.0 or 1.0 on soft pwm")
|
||||
self._pwm_max = float(cycle_ticks)
|
||||
if self._is_static:
|
||||
self._mcu.add_config_cmd("set_digital_out pin=%s value=%d"
|
||||
% (self._pin, self._start_value >= 0.5))
|
||||
return
|
||||
self._oid = self._mcu.create_oid()
|
||||
self._mcu.add_config_cmd(
|
||||
"config_soft_pwm_out oid=%d pin=%s cycle_ticks=%d value=%d"
|
||||
" default_value=%d max_duration=%d"
|
||||
% (self._oid, self._pin, cycle_ticks,
|
||||
self._start_value >= 1.0, self._shutdown_value >= 0.5,
|
||||
self._mcu.seconds_to_clock(self._max_duration)))
|
||||
curtime = self._mcu.get_printer().get_reactor().monotonic()
|
||||
printtime = self._mcu.estimated_print_time(curtime)
|
||||
self._last_clock = self._mcu.print_time_to_clock(printtime + 0.100)
|
||||
svalue = int(self._start_value * self._pwm_max + 0.5)
|
||||
self._mcu.add_config_cmd(
|
||||
"schedule_soft_pwm_out oid=%d clock=%d on_ticks=%d"
|
||||
% (self._oid, self._last_clock, svalue), is_init=True)
|
||||
self._set_cmd = self._mcu.lookup_command(
|
||||
"schedule_soft_pwm_out oid=%c clock=%u on_ticks=%u",
|
||||
cq=cmd_queue)
|
||||
def set_pwm(self, print_time, value):
|
||||
clock = self._mcu.print_time_to_clock(print_time)
|
||||
if self._invert:
|
||||
|
|
Loading…