docs: Minor updates to SmartEffector docs
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
2060a6908f
commit
05330fd3e5
|
@ -1747,10 +1747,12 @@ control_pin:
|
|||
```
|
||||
|
||||
### [smart_effector]
|
||||
Smart Effector. One may define this section instead of `[probe]` to enable
|
||||
the SmartEffector-specific features. This also enables
|
||||
[runtime commands](G-Codes.md#smart-effector) to adjust the parameters of
|
||||
the Smart Effector at run time.
|
||||
|
||||
The "Smart Effector" from Duet3d implements a Z probe using a force
|
||||
sensor. One may define this section instead of `[probe]` to enable the
|
||||
Smart Effector specific features. This also enables
|
||||
[runtime commands](G-Codes.md#smart_effector) to adjust the parameters
|
||||
of the Smart Effector at run time.
|
||||
|
||||
```
|
||||
[smart_effector]
|
||||
|
|
|
@ -1064,18 +1064,19 @@ before changing the Smart Effector parameters. Also check the
|
|||
|
||||
#### SET_SMART_EFFECTOR
|
||||
`SET_SMART_EFFECTOR [SENSITIVITY=<sensitivity>] [ACCEL=<accel>]
|
||||
[RECOVERY_TIME=<time>]`: Set the Smart Effector parameters. When `SENSITIVITY`
|
||||
is specified, the respective value is written to the SmartEffector EEPROM
|
||||
(requires `control_pin` to be provided). Acceptable <sensitivity> values are
|
||||
0..255, the default is 50. Lower values require less nozzle contact force to
|
||||
trigger (but there is a higher risk of false triggering due to vibrations
|
||||
during probing), and higher values reduce false triggering (but require larger
|
||||
contact force to trigger). Since the sensitivity is written to EEPROM, it is
|
||||
preserved after the shutdown, and so it does not need to be configured on
|
||||
every printer startup. `ACCEL` and `RECOVERY_TIME` allow to override the
|
||||
corresponding parameters at run-time, see the
|
||||
[config section](Config_Reference.md#smart-effector) of Smart Effector for
|
||||
more info on those parameters.
|
||||
[RECOVERY_TIME=<time>]`: Set the Smart Effector parameters. When
|
||||
`SENSITIVITY` is specified, the respective value is written to the
|
||||
SmartEffector EEPROM (requires `control_pin` to be provided).
|
||||
Acceptable `<sensitivity>` values are 0..255, the default is 50. Lower
|
||||
values require less nozzle contact force to trigger (but there is a
|
||||
higher risk of false triggering due to vibrations during probing), and
|
||||
higher values reduce false triggering (but require larger contact
|
||||
force to trigger). Since the sensitivity is written to EEPROM, it is
|
||||
preserved after the shutdown, and so it does not need to be configured
|
||||
on every printer startup. `ACCEL` and `RECOVERY_TIME` allow to
|
||||
override the corresponding parameters at run-time, see the
|
||||
[config section](Config_Reference.md#smart_effector) of Smart Effector
|
||||
for more info on those parameters.
|
||||
|
||||
#### RESET_SMART_EFFECTOR
|
||||
`RESET_SMART_EFFECTOR`: Resets Smart Effector sensitivity to its factory
|
||||
|
|
Loading…
Reference in New Issue